
4. Parameters
4-22
Example of Changing Output Signal Allocation
The following is an example of output signal allocation change.
The sequence of switching the allocation signals of ALARM (CN1-38/39) and ZSPD (CN1-
43) is as follows:
Before Changing
After Changing
[P2-05]:
Order
Loader Window Display
Result
Keys to Use
What to Do
1
Press [MODE] to move to [P2-05].
2
Press [SET] to enter parameter
edit mode. The parameter is
displayed as 04321.
3
Press [UP] or [DOWN] at the
blinking cursor to change the
number to 04323.
4
Press [/LEFT] or [/RIGHT] at the
blinking cursor to move to the
desired digit, DIGIT 3.
5
Press [UP] or [DOWN] at the
blinking cursor to change the
number to 04123.
6
Hold down [SET] for approximately
one second. After two flickers, the
number will be saved as 04123 for
the parameter.
7
Hold down [MODE] for
approximately one second to
return to [P2-05].
8
** Modification is not possible with the servo on & Reset the parameter.
※
In case of exiting without
saving the set value
Hold down [MODE] for
approximately one second to
return to the parameter.
NOTE 1)
“ ” indicates flickering.
If two output signals are allocated to a number, the output contact setting error [AL-72] alarm
will be triggered.
Содержание L7 A001
Страница 1: ...VER 1 5...
Страница 2: ......
Страница 32: ...1 Product Components and Signals 1 20...
Страница 38: ...2 Installation 2 6...
Страница 54: ......
Страница 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Страница 210: ...8 Maintenance and Inspection 8 14...
Страница 211: ...9 Appendix 9 1 9 Appendix...
Страница 218: ...9 Appendix 9 8...
Страница 221: ......
Страница 222: ......