5. Handling and Operation
5-10
5.2.8
Input Contact Forced ON/OFF [Cn-07]
The drive forcibly turns on/off the input contact without an upper level controller or I/O jig.
(1)
Input Contact Forced ON/OFF Setting
The positions of the seven segment LEDs and CN1 contacts correspond as follows.
If an LED that corresponds to a contact is turned on/off, it indicates ON/OFF accordingly.
[Input Contact Setting]
Number
(A)
(9)
(8)
(7)
(6)
(5)
(4)
(3)
(2)
(1)
CN1
pin
number
48
18
19
20
46
17
21
22
23
47
Allocated
default
signal
name
STOP
EMG
CWLIM
CCWLIM
DIR
ALMRST
SPD3
SPD2
SPD1
SVON
Press [UP] on each digit and the (A), (8), (6), (4), and (2) signals turn on or off forcibly.
Press [DOWN] on each digit and the (9), (7), (5), (3), and (1) signals turn on or off forcibly.
Press [MODE] to move to another digit.
(2)
Example of Input Contact Forced ON/OFF
(SVON ON → EMG ON → EMG OFF → SVON OFF)
[Example of handling input contact forced ON/OFF]
Order
Loader Displays
Keys to Use
What to Do
1
Press [MODE] to move to [Cn-00].
2
Press [UP] or [DOWN] to move to
[Cn-07].
3
Press [SET] to enter input forced
ON/OFF mode.
4
Press [SET] to enter forced input bit
setting.
Содержание L7 A001
Страница 1: ...VER 1 5...
Страница 2: ......
Страница 32: ...1 Product Components and Signals 1 20...
Страница 38: ...2 Installation 2 6...
Страница 54: ......
Страница 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Страница 210: ...8 Maintenance and Inspection 8 14...
Страница 211: ...9 Appendix 9 1 9 Appendix...
Страница 218: ...9 Appendix 9 8...
Страница 221: ......
Страница 222: ......