Chapter 9. Trouble Shooting
9-14
9.2.12 Error code E05-01: Time out error in GMWIN communication
End
Check the
disconnection and
connection of cable.
Is there any problem in the
connection of RS-232C
cable?
Is communication port
correctly set?
Are
the network type,
slot, and station number
correct during link
setting?
Is the module of
appropriate slot set
according to the
network type?
Is there any problem
in network
configuration?
Contact Service station.
Set again the port to be
used for GMWIN
communication.
Correct the station
number or appropriate
slot number.
Correct network type or
slot number of
appropriate slot.
Check and correct it
according to the flow of
error code E01-01.
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
GMWIN communication error
Содержание G0L-GWRA
Страница 115: ...Appendix A 14 A3 5 G0L GWRA Applied type G0L GWRA ...