Using Protection Features
348
trip history will not be stored after the reset.
Set PRT-
82 (LV2 Enable) to “11” to store the trip history.
Low Voltage 2 Trip Details
Code
Description
PRT-82
Set options for Low Voltage2 trip operation.
Bit setting
Function
Disable Low Voltage2 trip (Low Voltage trip is
used).
Enable Low Voltage2 trip but do not store the trip
history.
Disable Low Voltage2 trip (Low Voltage trip is
used).
Enable Low Voltage2 trip and store the trip history.
10.3
List of Faults and Warnings
The following list shows the types of faults and warnings that can occur while using the iS7
inverter.
Category
LCD Display
Details
Major fault
Latch type
Over Current1
Over current trip
Over Voltage
Over voltage trip
External Trip
Trip due to an external signal
NTC Open
Temperature sensor fault trip
Over Current2
ARM short current fault trip
Fuse Open
Fuse open trip
Option Trip-x
Option fault trip
Over Heat
Over heat fault trip
Out Phase Open
Output open-phase fault trip
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...