![LS ELECTRIC SV-iS7 Series Скачать руководство пользователя страница 345](http://html1.mh-extra.com/html/ls-electric/sv-is7-series/sv-is7-series_user-manual_1943801345.webp)
Using Protection Features
328
To protect the motor from overload faults, the inverter output frequency is adjusted
automatically, based on the size of load.
Group Code
LCD Display
Parameter Setting Setting Range
Unit
PRT
50
Stall Prevent &
Flux Braking
-
0 0000
-
Bit
51
Stall Freq 1
-
60.00
Starting Freq
–
Stall Freq 1
Hz
52
Stall Level 1
-
180
30
–
250
%
53
Stall Freq 2
-
60.00
Stall Freq 1
–
Stall Freq 3
Hz
54
Stall Level 2
-
180
30
–
250
%
55
Stall Freq 3
-
60.00
Stall Freq 2
–
Stall Freq 4
Hz
56
Stall Level 3
-
180
30
–
250
%
57
Stall Freq 4
-
60.00
Stall Freq 3
–
Max. Freq
Hz
58
Stall Level 4
-
180
30
–
250
%
OUT
31
–
33
Relay1,2, Q1
9
Stall
-
-
Stall Prevention Function and Flux Braking Setting Details
Code
Description
PRT-50 Stall
Prevent
Stall prevention can be configured for acceleration, deceleration, or while operating
a motor at constant speed. When the LCD segment is on, the corresponding bit is
off.
Item
Bit Status (On)
Bit Status (Off)
Keypad display
Setting
Function
Bit5
Bit 4
Bit 3
Bit 2
Bit 1
Stall protection during acceleration
Stall protection while operating at a constant speed
Stall protection during deceleration
Flux braking during deceleration
Stall protection during acceleration & constant
speed
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...