Using Monitor Functions
318
Code
Description
21
Seq Pulse
Outputs a signal when a sequence is completed in an auto
sequence operation.
22
Ready
Outputs a signal when the inverter is in standby mode
and ready to receive external operation commands.
23
Trv ACC
Outputs a signal when the inverter reaches the
accelerating frequency during a traverse operation.
Group Code LCD Display
Parameter
setting
Unit
APP
01
App Mode
1 Traverse
-
24
Trv DEC
Outputs a signal when the inverter reaches the
decelerating frequency during a traverse operation.
Group Code LCD Display
Parameter
setting
Unit
APP
01
App Mode
1 Traverse
-
25
MMC
Used as a multi-motor control function. By configuring the
relay output and the multi-function output to MMC and
configuring the APP-01 (APP Mode) to
“
3 (MMC), it can
conduct the necessary operations for multi-motor control
function.
Group Code LCD Display
Parameter
setting
Unit
APP
01
App Mode
3 MMC
-
26
Zspd Dect
Detects if
the motor’s
rotation speed is 0 rpm during
operation and if the control mode is set as a vector.
Group Code LCD Display
Parameter
setting
Unit
DRV
09
Control Mode
4
Vector
-
CON
82
ZSD Frequency -
2.00
Hz
83
ZSD Band (Hz)
-
1.00
Hz
As the relay operation is dependent on the motor number
(encoder signal), a fault may occur when turning the
inverter on or off due to the encoder signal noise or filter
time constant.
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...