Using Monitor Functions
9.2.2
Monitoring Fault Trip History
The types of up to five previous fault trips can be saved and monitored. The lower the number
of Last X is, the more recent the fault it represents. If more than 5 faults occur, those occurring
before the last 5 are automatically deleted.
The items displayed in the fault trip history are listed in the following table.
Displayed Information
Description
0
Trip Names(1)
Displays the fault types.
1
Output Freq
The operating frequency at the time of the fault occurrence.
2
Output Current
The output current at the time of the fault occurrence.
3
Inverter State
Displays acceleration, deceleration, constant speed operation, and
stop state.
4
DCLink Voltage
Displays the i
nverter’s DC power voltage
.
5
Temperature
Displays the i
nverter’s temperature
.
6
Input State
Displays the input terminal’s status
.
7
Output State
Displays the output terminal’s status
.
8
Trip On Time
Displays the time from the power ON to the fault occurrence.
9
Trip Run Time
Displays the time from Run to the fault occurrence.
10 Trip Delete ?
Displays whether the currently saved fault trip history is to be deleted.
There are two ways to delete the fault trip history.
At each fault trip,
To delete the individual fault trip, select “Yes” at TRP
-10 (Trip Delete?). Also, to
delete the entire fault trip history, select “Yes” at CNF
-24 (Erase All Trip).
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...