Learning Advanced Features
Adv
anc
ed
Feat
ur
es
229
1
Totem or
Com
Totem pole output
2
Open
Collector
Open collector output
APO-05 Enc Pulse Sel
Sets the direction of the encoder output pulse.
0: A+B (Fx, for frequency reference) / 1: -(A+B) (Rx)
APO-06 Enc Pulse Num Sets the number of output pulses per one motor revolution.
APO-08 Enc Monitor
Converts the encoder output into motor speed (Hz or RPM) for
monitoring.
8.10
V/F Operation Using Speed Sensor
You can install an optional encoder module to the inverter to enhance the accuracy of V/F
control. Before operating the inverter, check the encoder connection by running an auto
tuning operation.
Group Code
Name
LCD Display
Parameter Setting Setting Range Unit
DRV
09
Control mode
Control Mode
1 V/F PG
0
–
5
-
CON
45
PG operation
proportional gain
PG P-Gain
-
3000
0
–
9999
-
46
PG operation
integral gain
PG I-Gain
-
50
0
–
9999
-
47
PG operation
maximum slip
PG Slip Max %
-
100
0
–
200
%
APO
01
Encoder option
mode
Enc Opt Mode
1 Feed-back
0
–
2
-
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...