![LS ELECTRIC SV-iS7 Series Скачать руководство пользователя страница 176](http://html1.mh-extra.com/html/ls-electric/sv-is7-series/sv-is7-series_user-manual_1943801176.webp)
Basic Functions
159
B
as
ic
Func
tio
ns
7.5.3
The Terminal Block as a Command Input Device (Run and
Rotation Direction Commands)
Multi-function terminals can be selected as a command input device. This is configured by
setting DRV-
06 (command source) to “2 (Fx/Rx
-
2)”. Select two terminals for run and rotation
direction commands, and then set the relevant codes (2 of the 11 multi-function terminal codes,
IN-65
–
75 for P1
–
P11 [optional: P9
–
P11]
) to “1 (Fx)” and “2 (Rx)” respectively. This application uses
an Fx input as a run command, and an Rx input to change a motor’s rotation direction (On:
Rx,
Off: Fx).
Group Code
Name
LCD Display
Parameter Setting Setting Range Unit
DRV
06
Command source Cmd Source
2
Fx/Rx-2
0
–
5
-
IN
65
–
75
Px terminal
configuration
Px Define (Px:
P1
–
P8
[optional: P9
–
P11])
1
Fx
-
-
2
Rx
88
Delay time setting Run On Delay -
1.00
0.00
–
100.00
Sec
Run Command and Fwd/Rev Change Command Using Multi-function Terminal
–
Setting Details
Code
Description
DRV-06 Cmd Source
Set to “2 (Fx/Rx
-
2)”.
IN-65
–
75 Px Define
Assign a terminal for the run command (Fx).
Assign a terminal for changing the rotation direction (Rx).
IN-88 Run On Delay
Set the delay time if the inverter operation needs to be synchronized
with other sequences. When the run command input (Fx/Rx) is given,
the operation begins after the set time has elapsed.
Содержание SV-iS7 Series
Страница 17: ......
Страница 22: ...About the Product 5 1 2 2 Interior and Exterior View IP 54 Model Types Less than 22 kW 200 400 V ...
Страница 114: ...Peripheral Devices 97 Group 2 ...
Страница 115: ...Peripheral Devices 98 Group 3 ...
Страница 116: ...Peripheral Devices 99 Group 4 ...
Страница 153: ...Using the Keypad 136 The Parameter Initialization option is displayed again when the initialization is complete ...
Страница 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Страница 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...