Detailed operation by function groups
248
Note
After jumping directly to a co
de, you can move to other codes by pressing [▲]
or [▼].
6.6.2 Speed controller PI ratio
Code
Keypad display
Name
Range
Unit
Parameter
setting
CON_02 ASR PI Ratio
Speed controller gain ratio
1.0–500.0
%
20.0
CON_02 is only used with a synchronous motor.
6.6.3 Speed controller (Automatic Speed Regulator:
ASR)
Speed controller PI gain 1 (CON_03–04)/Speed Controller PI gain 2
(CON_06–07)
When you switch two types of speed controller PI gain, LPF time constant
(speed command value) also changes according to the selected gain. If the
multifunction input terminal is set to OFF, the gain1 and LPF time constant are
selected. If the multifunction input terminal is set to ON, the gain2 and LPF time
constant are selected.
The following table lists the examples of code settings when multifunction
terminal P4 is set for ASR PI Gain switching.
Code
Keypad display
Name
Range
Unit
Default setting
DIO_04
P4 define
Multifunction input terminal
P4 Definition
ASR Gain Sel
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...