Detailed operation by function groups
147
O
p
er
ati
o
n
D
etai
ls
•
To gain access to other groups, press [Mode] to display password input
screen (PAR_05). Once a correct password is entered, all the other codes
become accessible again.
•
Set PAR_05 to “0” to disable the password option.
The master password for the inverter is “5052”. Use the master password to
disable the password option and gain access to the codes in case you cannot
remember the password. Upon entering the master code, PAR_05 is set to “0”
and automatically disables the password option.
Code
Keypad display
Name
Range
Unit
Default setting
PAR_05 Password
Password
0–255
0
6.2.3 Motor-related settings
6.2.3.1 Control mode options (PAR_07)
The L100 inverter provides speed control modes such as “Speed(IM)” and
“Speed (PM)” beside the open-loop control modes such as “V/F” and “Slip
Comp.”
To operate the inverter in speed control mode (Speed(IM) or Speed(PM)), a
speed feedback device (encoder) must be installed.
Code
Keypad display Name
Range
Unit
Default setting
PAR_07 Control Mode
Control mode options
2 (Speed(IM))
4 (V/F)
4 (V/F)
5 (Slip Comp)
6 (Speed(PM))
Содержание LSLV-L100 Series
Страница 16: ...3 Preparing the Installation Preparation ...
Страница 36: ...Installing the Inverter 23 Installation Power terminal and control terminal wiring diagram ...
Страница 240: ...Detailed operation by function groups 227 Operation Details BX time FUN_51 set to a value other than 0 ...
Страница 252: ...Detailed operation by function groups 239 Operation Details stops When forward operation has a lighter load ...
Страница 339: ...326 Communication features CAN message frame versions CAN 2 0A CAN 2 0B ...
Страница 395: ...382 ...