![LS ELECTRIC LSLV-H100 Series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/ls-electric/lslv-h100-series/lslv-h100-series_user-manual_1943798091.webp)
78
Learning Basic Features
4 Learning Basic Features
This chapter describes the basic features of the H100 inverter. Check the reference page in
the table to see the detailed description for each of the advanced features.
Basic Tasks
Description
Ref.
Operation mode selection
(HAND / AUTO / OFF)
Used to select the operation mode.
Frequency reference
source configuration for
the keypad
Configures the inverter to allow you to setup or modify
a frequency reference using the Keypad.
Frequency reference
source configuration for
the terminal block (input
voltage)
Configures the inverter to allow input voltages at the
terminal block (V1, V2) and to setup or modify a
frequency reference.
Frequency reference
source configuration for
the terminal block (input
current)
Configures the inverter to allow input currents at the
terminal block (I2) and to setup or modify a frequency
reference.
Frequency reference
source configuration for
the terminal block (input
pulse)
Configures the inverter to allow input pulse at the
terminal block (TI) and to setup or modify a frequency
reference.
Frequency reference
source configuration for
RS-485 communication
Configures the inverter to allow communication signals
from upper level controllers, such as PLCs or PCs,
and to setup or modify a frequency reference.
Frequency control using
analog inputs
Enables the user to hold a frequency using analog
inputs at terminals.
Motor operation display
options
Configures the display of motor operation values.
Motor operation is displayed either in frequency (Hz) or
speed (rpm).
Multi-step speed
(frequency) configuration
Configures multi-step frequency operations by
receiving an input at the terminals defined for each
step frequency.
Command source
configuration for keypad
buttons
Command source configuration for keypad buttons.
Command source
configuration for terminal
Configures the inverter to accept inputs at the FX/RX
terminals.
Содержание LSLV-H100 Series
Страница 17: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Страница 18: ...Preparing the Installation 5 110 132 kW 3 Phase ...
Страница 19: ...Preparing the Installation 6 160 185 kW 3 Phase ...
Страница 20: ...Preparing the Installation 7 220 250 kW 3 Phase ...
Страница 21: ...Preparing the Installation 8 315 400 kW 3 Phase ...
Страница 22: ...Preparing the Installation 9 500 kW 3 Phase ...
Страница 35: ...Installing the Inverter 22 ...
Страница 50: ...37 Installing the Inverter Input and Output Control Terminal Block Wiring Diagram ...
Страница 104: ...91 Learning Basic Features 0 10 V Input Voltage Setting Details V1 Quantizing ...
Страница 181: ...168 Learning Advanced Features PID Command Block ...
Страница 182: ...169 Learning Advanced Features ...
Страница 183: ...170 Learning Advanced Features PID Feedback Block ...
Страница 184: ...171 Learning Advanced Features PID Output Block ...
Страница 185: ...172 Learning Advanced Features PID Output Mode Block ...
Страница 198: ...185 Learning Advanced Features EPID1 Control block ...
Страница 199: ...186 Learning Advanced Features EPID2 Control block ...
Страница 220: ...207 Learning Advanced Features ...
Страница 235: ...222 Learning Advanced Features The Time Chart for the Exception Day ...
Страница 506: ...Table of Functions 493 ...
Страница 520: ...Table of Functions 507 8 16 4 Cooling Tower MC4 Group ...
Страница 549: ...Troubleshooting 536 ...
Страница 569: ...Technical Specification 556 11 3 External Dimensions 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Страница 570: ...Technical Specification 557 110 185 kW 3 phase ...
Страница 601: ...588 ...
Страница 602: ...589 ...
Страница 603: ...590 ...