RS-485
Communication Features
339
7 RS-485 Communication Features
This section in the user manual explains how to control the inverter with a PLC or a
computer over a long distance using the RS-485 communication features. To use the RS-
485 communication features, connect the communication cables and set the
communication parameters on the inverter. Refer to the communication protocols and
parameters to configure and use the RS-485 communication features.
7.1 Communication Standards
Following the RS-485 communication standards, H100 products exchange data with a PLC
and computer. The RS-485 communication standards support the Multi-drop Link System
and offer an interface that is strongly resistant to noise. Please refer to the following table for
details about the communication standards.
Item
Standard
Communication method/
Transmission type
RS-485/Bus type, Multi-drop Link System
Inverter type name
H100
Number of connected
inverters/ Transmission
distance
Maximum of 16 inverters / Maximum1,200 m (recommended
distance: within 700 m)
Recommended cable size 0.75 mm², (18 AWG), Shielded Type Twisted-Pair (STP) Wire
Installation type
Dedicated terminals (S+/S-/SG) on the control terminal block
Power supply
Supplied by the inverter - insulated power source from the
inverter’s internal circuit
Communication speed
1,200/2,400/4800/9,600/19,200/38,400/57,600/115,200 bps
BACNET: 9600/19200/38400/76800 bps
Control procedure
Asynchronous communications system
Communication system
Half duplex system
Character system
Modbus-RTU: Binary / LS Bus: ASCII
Stop bit length
1-bit/2-bit
Frame error check
2 bytes
Parity check
None/Even/Odd
Содержание LSLV-H100 Series
Страница 17: ...Preparing the Installation 4 37 90 kW 3 Phase ...
Страница 18: ...Preparing the Installation 5 110 132 kW 3 Phase ...
Страница 19: ...Preparing the Installation 6 160 185 kW 3 Phase ...
Страница 20: ...Preparing the Installation 7 220 250 kW 3 Phase ...
Страница 21: ...Preparing the Installation 8 315 400 kW 3 Phase ...
Страница 22: ...Preparing the Installation 9 500 kW 3 Phase ...
Страница 35: ...Installing the Inverter 22 ...
Страница 50: ...37 Installing the Inverter Input and Output Control Terminal Block Wiring Diagram ...
Страница 104: ...91 Learning Basic Features 0 10 V Input Voltage Setting Details V1 Quantizing ...
Страница 181: ...168 Learning Advanced Features PID Command Block ...
Страница 182: ...169 Learning Advanced Features ...
Страница 183: ...170 Learning Advanced Features PID Feedback Block ...
Страница 184: ...171 Learning Advanced Features PID Output Block ...
Страница 185: ...172 Learning Advanced Features PID Output Mode Block ...
Страница 198: ...185 Learning Advanced Features EPID1 Control block ...
Страница 199: ...186 Learning Advanced Features EPID2 Control block ...
Страница 220: ...207 Learning Advanced Features ...
Страница 235: ...222 Learning Advanced Features The Time Chart for the Exception Day ...
Страница 506: ...Table of Functions 493 ...
Страница 520: ...Table of Functions 507 8 16 4 Cooling Tower MC4 Group ...
Страница 549: ...Troubleshooting 536 ...
Страница 569: ...Technical Specification 556 11 3 External Dimensions 0 75 30 kW 3 phase 37 90 kW 3 phase ...
Страница 570: ...Technical Specification 557 110 185 kW 3 phase ...
Страница 601: ...588 ...
Страница 602: ...589 ...
Страница 603: ...590 ...