background image

 

 

 

Frequency Converter  

SpeedControl E 1045 

For use with specific motors 

 

 

 

 

 

 

 

 

 

Date: 19/11-2018 

Revision: 9 

Drawn by: FS and DF 

Manufactured by: LS Control A/S  

http://www.lscontrol.com 

Phone: +45 5550 5550 

Drawing: 949-206095_HIGHLY_vejledning_ES1045_rev9_UK 

 

Содержание SpeedControl E 1045

Страница 1: ... SpeedControl E 1045 For use with specific motors Date 19 11 2018 Revision 9 Drawn by FS and DF Manufactured by LS Control A S http www lscontrol com Phone 45 5550 5550 Drawing 949 206095_HIGHLY_vejledning_ES1045_rev9_UK ...

Страница 2: ...ors 3 Technical Specifications 4 EMC 4 Warnings 4 Description of Functions 6 Supply 6 Control Voltage 6 RUN input 6 DIR Input 6 LSC Input 6 Thermistor 6 Alarm Relay 6 HW Stop switch 7 Current Limits 7 Temperature 7 Skip areas 7 Electrical Mechanical Installation 8 Important 8 Location 8 Operating temperature 8 Supply 9 Motor 9 Signal Cables 9 Mounting 10 Indicator Lights 11 Modbus LED lights 11 Mo...

Страница 3: ...means of dip switches Since the compressor parameters change with changing loads LS Control must carry out a perform test on each individual compressor to select the best parameters covering the widest range of operating patterns ensuring that the compressor will be able to operate at high loads as well as low loads The result of the performance test will give a new max current and new max RPM for...

Страница 4: ...c test methods EN 61800 3 A1 2012 Adjustable speed electrical power drive systems Part 3 EMC requirements and specific test methods EN 61800 5 1 2007 Adjustable speed electrical power drive systems Part 5 1 Safety requirements Electrical thermal and energy If a frequency converter is purchased in no enclosure IP00 LS Control can t ensure that the frequency converter complies with the above standar...

Страница 5: ...machine solution the machine manufacturer is responsible for providing the machine with a main switch EN60204 1 If the frequency converter is disconnected from mains while the motor is running high and dangerous voltage may still be present on the frequency converter power unit In this case the motor is operating as a generator supplying the frequency converter with power After disconnecting the f...

Страница 6: ... g a Klixon or a thermistor By default it is setup for use with a thermal switch This can be changed via the ModBus interface See chapter on Modbus Thermal switch If LSC input is used with a thermal switch e g a Klixon connect thermal switch between connector 1 2 When the thermal switch is closed all is okay If thermal switch is open for more than 6 seconds a thermal Error is indicated and motor i...

Страница 7: ...s on the current and the overrun time which are integrated into the intelligent protection algorithm in the control Temperature The temperature function is set to ensure that if the frequency converter power unit registers an excess temperature it will reduce the motor speed However the speed will never be reduced further than the minimum speed The motor speed reduction will be slow Should the tem...

Страница 8: ...g free circulation of air Make sure that the mounting surface can withstand the temperature of the surface of the frequency converter Operating temperature The frequency converter must be installed in a well ventilated enviroment The surrounding temperature must not exceed 40 C and the frequency converter must never be mounted in a location where it is exposed to direct sun light The E1045 1500 wi...

Страница 9: ...high frequency radiation Supply Connection PE Protective grounding supply N Neutral supply L Live 230VAC supply Motor The motor is connected to the frequency converter by minimum 4 x 1 5 mm2 shielded cable The total cable length must not exceed 20 m keep it as short as possible Long cables may cause function failure The motor cable must be shielded and be mounted correctly in the metal gland or to...

Страница 10: ...550 Fax 45 5550 2265 www lscontrol com lsc lscontrol dk Mounting Mounting instruction for ES1045D PCB Note If thermal switch is not used shorten connector 1 2 If the thermistor is needed connect to connector 1 2 and setup through ModBus for thermistor use If HW Stop Switch not needed shorten connector 16 17 ...

Страница 11: ...e the motor selected by the DIP switches This also indicates that the motor in questions has been initialized in the processor 3 At last LED1 turns off and LED2 starts flashing Operation When there are no errors LED2 will be flashing LED2 flashes when the motor is running and when it is stopped This indicates that everything is running normally Errors If an error is detected the frequency converte...

Страница 12: ... and turn off LED4 At the same time the modbus registers 03x0009 and 03x0010 will be set to a value corresponding to the error Modbus register 03x0011 will be set if the frequency converter is unable to restart and resume operation The following errors will be indicated by LED3 and the modbus registers 03x0009 and 03x0010 Flash LED3 03x0009 Error code 03x0010 Error code2 Error type Description 1 0...

Страница 13: ...s If LSC input is detecting an error By default LSC input is setup for connection of a thermal switch and if it is not used terminals 1 and 2 must be shortened WEEE Electrical and electronic equipment contains material which may be hazardous to human health and environment if it is not handled correctly at disposal Electrical and electronic equipment is marked with a crossed out wheelie bin logo T...

Отзывы: