background image

Usage, Installation, Warranty and Service Information

Long Range Systems, LLC

4550 Excel Parkway, Suite 200 

Addison, TX 75001

800.437.4996 

www.pager.net

800.437.4996

1

2

3

4

5

6

7

8

9

10 11 12

0

PGR

PROG

ENTER

Long Range Systems

www.pager.net

T9550LCK

Long Range Systems

T9550 LCK

Paging System Transmitter

U S E R   M A N U A L

Содержание T9550 LCK

Страница 1: ... Range Systems LLC 4550 Excel Parkway Suite 200 Addison TX 75001 800 437 4996 www pager net 800 437 4996 1 2 3 4 5 6 7 8 9 10 11 12 0 PGR PROG ENTER Long Range Systems www pager net T9550LCK Long Range Systems T9550 LCK Paging System Transmitter USER MANUAL ...

Страница 2: ...uide 5 Paging 5 Paging All Call 5 System Settings 6 Setting the Vibration Mode 6 System Reset 6 Set Restaurant ID 6 Maintenance Functions 7 Range Test 7 Check the Transmitter Battery Level 7 Battery Charge 7 Programming Pagers 8 System Specifications 8 T9550 LCK 8 Rechargeable Pagers 8 Troubleshooting 9 Transmitter Unit 9 Pagers 9 Service Questions and Answers 10 Warranty 11 Long Range Systems 1 T...

Страница 3: ... kept readily available for managers and key staff GeneralInformation The T9550 LCK is an onsite paging system used to increase efficiency in operations by alerting key staff of immediate needs The pagers used with the system can vibrate once twice or three times NOTE The T9550 LCK only works with LRS Star Pagers Long Range Systems 2 T9550 LCK User Manual 1 2 3 4 800 437 4996 www pager net 1 4 Lon...

Страница 4: ...ector end into either of the side holes on the transmitter unit 4 Press hold for 5 seconds and release the power reset button located on the side of the trans mitter unit The keypad display will light 5 Within 5 10 seconds the display light will disappear signifying that the transmitter is charging The display screen will be blank 6 Upon completion of setup allow the keypad to fully charge for at ...

Страница 5: ...n the last row of the transmitter keypad PGR Used when entering pager numbers above 12 0 Used when entering pager numbers above 12 that contain a zero and when calling all pagers at once PROG Used to alter messaging modes and to check the battery level ENTER After entering pager numbers above 12 press ENTER to send the page Long Range Systems 800 437 4996 1 2 3 4 5 6 7 8 9 10 11 12 0 PGR PROG ENTE...

Страница 6: ...agers numbered 1 12 1 Press the pager number 2 The unit will automatically send a page For pagers numbered 13 and higher 1 Press PGR 2 Enter the pager number using the 0 9 keys 3 Press the ENTER key Page All Call If all staff pagers need to be called simultaneously 1 Press PGR 2 Press 0 0 0 3 Press the ENTER key Long Range Systems 5 T9550 LCK User Manual ...

Страница 7: ... reset before operating properly When the system is reset the Restaurant ID see pg 7 and vibration mode see pg 7 will be set to factory default To reset the transmitter to factory default 1 Press PROG 2 Enter 0 0 0 and press ENTER Set Restaurant ID NOTE The T9550 LCK is shipped factory defaulted in the most commonly used configuration The Restaurant ID factory default setting is 0 Your system may ...

Страница 8: ...sconnect barrel end of the power adapter from the transmitter unit 2 Press PROG and then ENTER The unit will show a number from 0 to 5 If plugged in it does not matter If the unit shows 4 or above the charge is adequate for normal use If the unit shows 3 it is ok for short term use 1 2 hours If the unit shows 2 or less including blank it must be recharged before use Battery Charge If the battery p...

Страница 9: ...nsure that it s programmed correctly See Basic Paging Operations pg 6 7 Repeat Steps 2 through 6 for each pager to program SystemSpecifications Notice Operation is subject to the following This device may not cause interference This device will accept any interference including interference that may cause undesired oper ation of the unit T9550 LCK Required Voltage One 110V outlet for the transmitt...

Страница 10: ...not visible on some or all charging slots review the following recom mendations to determine and solve the problem Make sure the pagers are completely inserted into the charging slot The power supply may be defective Try plugging the power supply used for the transmitter into the pager charger You may have more pagers charging on one power supply than recommended Only 25 pagers can be charged on o...

Страница 11: ...Long Range Sys tems at 800 437 4996 Normal Business Hours Monday Friday 8 30 am to 5 00 pm Central Time Weekend or Evening Emergencies Long Range Systems provides 24 7 live technical support Please keep in mind that replacement options are limited on weekends and holidays Long Range Systems 10 T9550 LCK User Manual ...

Страница 12: ... or omissions Specifications and other information contained within this document are subject to change without notice Long Range Systems LLC reserves the right to make changes without further notice to any products herein LRS LLC makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose nor does LRS LLC assume any liability arising out of t...