background image

1. connections / operation

2. settings

6. cycle

5. Discharge

  

N i M H   5 . 0 A       0 0 m 3 5 s
0 8 . 5 8 V             0 0 4 8 m A h

3. specification 

100-240V AC / 12V DC
ChArge-DisChArge-CyCle
1-14 Cells nimh/niCD
1-5 Cells lipo/liFepo

LA00043

user guiDe

Dimensions

[mm]

145x160x60

Autostart Timer

yes

Weight

[g]

600

Partial Charge Mode

yes

Input Voltage

[AC]

100-240V

Cycle Mode

yes

[DC]

11-15V

User Profile Memory

3

Charging Mode

Linear

LCD

16x2, blue backlit

Charging 

Capability

LiPo/LiFePo

1-5 cells

Acoustic Signal Type

Buzzer

NiMH/NiCd

1-14 cells

Buttons

4

Charge Current

[A]

0.1 - 5.0

Advanced Digital

yes

Trickle Current

[A]

0 -0.25

Multi-Protection-System

yes

Delta Peak

[mV]

5 - 200

DC Input Connection

Alligator Clamps

Discharge Current

[A]

0.1 -1.0

AC Input Connection

AC connector

Discharge 

Cut-Off Voltage

LiPo/LiFePo

2.5 - 14.0V

Output Connection

4.0mm jacket

NiMH/NiCd

0.9- 16.0V

LRP electronic GmbH, 

Wilhelm-Enssle-Str. 132-134, 73630 Remshalden, Germany

[email protected]    www.LRP.cc

Specifications subject to change without notice.

Dear Customer,
thank you for your trust in this LRP product. By purchasing a LRP QUADRA-PRO Professional Battery Manag-

ment System, you have chosen a high-performance product which has the latest technology incorporated 

including the following High-Tech features:

• NiMH - NiCd - LiPo - LiFePo Charging 

• Dual Input (100- 12Vdc)

• NiMH - NiCd - LiPo - LiFePo Discharging 

• Blue backlit 16x2 LCD

• Cycle Mode 

• Partial Charge & Autostart Mode

• Microprocessor Controlled 

• 3 User Profile Memories

• 25-Year Warranty 

• Multi-Protection-System

Please read the following instructions carefully before you start using your LRP QUADRA-PRO charger. This 

user guide contains important notes for the installation, the safety, the use and the maintenance of this pro-

duct. Thus protecting yourself and avoid damages of the product.

Proceed according to the user guide in order to understand your LRP QUADRA-PRO charger better. Please take 

your time as you will have much more joy with your product if you know it exactly.

This user manual shall be kept in a safe place. If another customer is using this product, this manual has to be 

handed out together with it.

Order.NO.

41280

 

DC INPUT:

 

connect to a suitable DC source 

with 11-15V, using the supplied connection wire.

Caution:

 Be careful with correct polarity!

- Red = Plus

- Black = Minus

OUTPUT  JACKET:

  connect  battery  to 

be charged to the 4.0mm jacket, using sup-

plied charge wires.

Caution: 

Be careful with correct polarity!

AC INPUT:

 connect to main power 

with 100-240VAC

Caution:

 Do not alter the wire or con-

nector as this will void your warranty!

4. charge

SET Battery Type: 

The QUADRA-PRO can charge 4 different cell types and incorporates the designated 

charge algorithms for each particular cell type for best performance, reliability and safety.

NiMH/NiCd 

 charging with constant c delta-peak detection.

 This is the most popular charging 

method for NiMH/NiCd-batteries in competition.

LiPo/LiFePo 

 charging using the CC/CV-charging method.

 With this charging method, the battery gets 

charged with a constant current first. As soon as the battery voltage reaches the max. charging 

voltage of the LiPo- (4.2V/cell) or LiFePo- (3.7V/cell) battery, the charger automatically reduces 

the charging current till the battery is fully charged.

Caution:

  Always  choose  the  correct  BATTERY  TYPE  setting  for  the  battery  you  want  to  charge,  as  wrong 

setting may result in damage to the battery, fire or explosion!

SET Charge Current:

 The charge current can be set from 0.1 to 5.0A. If not otherwise specified by the 

battery manufacturer, choose 0.5C charge rate which is always a safe value!

SET Charge Delta Peak: 

With NiMH/NiCd-batteries, you only obtain the optimum battery performance 

by slightly „overcharging“ the battery. In real terms, it will not be overcharged, but charged to an optimum 

level. The battery voltage drops at the end of the charging process (delta). The size of the drop (delta peak) is 

adjustable in the range between 5 - 200mV. The higher the value, the hotter the battery will be at the end of the 

charge. We recommend to start with the works-default settings.

Note

The adjustable Delta-Peak value applies to the whole battery pack and not to one single cell!

SET Charge Trickle: 

This current, which flows after delta peak cutoff, is adjustable from 0.0A to 0.25A to 

achieve the highest possible voltage for NiCd cells. Set this function to „Off“ for NiMH cells.

User Profile

P1

P2

P3

Battery Type

NiMH

NiCd

LiPo

Charge Current

4.0A

3.0A

2.0A

Charge D-Peak

20mV

50mV

--

Charge Trickle

0ff

Off

--

Charge LiPo Volt

--

--

7.4V

Discharge Current

1.0A

1.0A

1.0A

Discharge Voltage

5.4V

5.4V

6.0V

The  active  profile  P1,  P2  or  P3  is  displayed 

in the main menu. By pressing the INC+ and 

DEC-  buttons  you  can  change  between  the 

profiles and their settings.

To reset your QUADRA-PRO to works-default 

settings, proceed as follows:
•  Disconnect input voltage.
•  Hold down MENU button while reconnec-

ting the input voltage.

The  QUADRA-PRO  allows  you  to  save  3  individual  user  profiles.  This  means  you  can  customize  3  personal 

charge profiles individually and store them for later use. The QUADRA-PRO has 3 preset works-default settings 

when shipped out: P1 (NiMH), P2 (NiCd), P3 (LiPo 2-cell). For details see the table below.

The QUADRA-PRO was developed with the main objective placed on easy operation of all features. Intuitive 

navigation by means of 4 buttons makes it very easy to use and the 2-line blue backlit LC display offers perfect, 

reliable control of all settings and functions.

BUTTONS:

MENU

 

Scrolls/jumps through the function list.

DEC -

 

Decrements the underscored value.*

INC +

 

Increments the underscored value.*

START/STOP

 

Next program step / Start a program / Cancel a running program.

* Button has high-speed function for rapid setting (hold down button to change value faster).

The adjustable discharge circuit (0.1 to 1.0A) can be used for 1-14 cell NiMH/NiCd-packs and 1-5 cell LiPo/

LiFePo-packs. The QUADRA-PRO informs you about all the data relating to the battery pack, e.g. discharge 

time, capacity and average voltage.

By discharging your battery pack on the QUADRA-PRO after use, you obtain vital information about remaining 

capacity for optimizing your motor or gear ratio for the next run. This also maintains your battery packs in good 

condition.

SET Discharge Current: 

The discharge current can be set from 0.1 - 1.0A.

SET Discharge Voltage: 

The cut-off voltage can be adjusted from 0.9 - 14.0V depending on the number 

of cells. We recommend a cut-off voltage of 0.9V/cell with NiMH/NiCd-, 3.0V/cell with LiPo-and 2.6V/cell with 

LiFePo-batteries. This means for example

- 5.4V for 6-cell NiMH/NiCd

- 6.0V for a 2-cell LiPo

- 5.2V. for a 2-cell LiFePo

This fully automatic cycling/matching function allows you to determine the actual performance of your packs 

before using them. Battery packs change during their life span. Use the QUADRA-PRO to detect the actual 

quality of your packs. This prevents nasty surprises.

The “Cycle” mode uses the charge and discharge values of the currently selected programm, stored under 

“Settings”. The pack is first discharged, then charged and finally discharged. At the end of the process, the pack 

capacity and the average discharge voltage are displayed.

There is a short delay in the timer during cycle operation, in order not to overheat the batteries, which is as 

following:

  - Initial Discharge -> Charge: 1min (if discharge was finished within 10min), otherwise 5min

  - Charge -> Discharge: 1min (if charge was finished within 10min), otherwise 5min

Note:

 The „Cycle“ function can of course be used for all types of cells (NiMH-NiCd-LiPo-LiFePo).

© LRP electronic GmbH 2008

16x2 LCD SCREEN:

Active function

Time elapsed since start

Current

Capacity

Voltage at output connectors

Cell#

LiPo

LiFePo

1

3.7V

3.3V

2

7.4V

6.6V

3

11.1V

9.9V

4

14.8V

13.2V

5

18.5V

16.5V

SET Charge LiPo/LiFePo Volt (pack voltage): 

The packs 

rated voltage for LiPo- and LiFePo-batteries must be set according to 

the packs number of cells. See right table.

*  C=Nominal  capacity  of  the  battery.  E.g.  with  a  nominal  capacity  of  3300mAh 

(3,3Ah), the battery can be charged with a max. current of 3,3A.:

Отзывы: