background image

connections

technical data

touchscreen usage

factory defaults

balancer connection

 

 

P1 PROFILE NAME    

.

    

 

 

    LINEAR CHARGE 
 

 
 

 

 

SETUP 

 START 

Connection Example 3S:

Connection Example 4S:

 

 P1 CHARGE    [1/2] X 

Chg Mode   :  Linear 

Current    :    4.0A 
DPeak      :    20mV 

Trickle    :     Off 
Safety Time:   90min 
 

SET

 

 

 

 

 

NEXT

 

 

 P1 CHARGE    [2/2] X

 

Cut-Temp :      55°C

 

 
 

 
 
 
 
 

SET

 

 

 

 

 

NEXT

 

 

_

XXXX CHARGE   02m30s 

 Capacity      250mAh 

Current        6.00A 

Voltage        7.82V 
Resistance     0.0m

 

Temperature    0.0°C 

 

 

 

_

XXXX CHARGE   02m30s 

 Capacity      250mAh 

Current        6.00A 

Voltage        7.82V 
Resistance     0.0m

 

Temperature    0.0°C 

 

  

 

 

 

 

NEXT

 

STOP

 

 

 P1 PROFILE NAME    X  

    

 

ABCDEFHIJKLMNO

P

QR    

STUVWXYZabcdefghi     
jklmnopqrstuvwxyz     

0123456789-._’#+/    

 

 

 

DEL

 

 

 

 

OK 

 

 

P1 PROFILE NAME    

.

    

 

 

    LINEAR CHARGE 
 
 

 

 

 

SETUP 

 START 

 

_

XXXX CHARGE   02m30s 

 Capacity      250mAh 

Current        

6.00A 

Voltage        7.98V 

Resistance     0.0m

 

Temperature    0.0°C 

 

 

STOP

 

 

 

 

 

NEXT

 

Dear Customer,
thank you for your trust in this LRP product. By purchasing a 

LRP Pulsar Touch

, you have chosen a high-performance product 

which has the latest technology incorporated including the following High-Tech features:

• Professional Multi-Function System (Charge, Discharge, Cycle, Balance, Motor/ESC/Servo Check)

• up to 12.0A Charge Current 

• up to 20.0A discharge current (+ 35A Pulse Discharge)

• LiPo • LiFePo • NiMH • NiCd 

• Integrated Balancer for 2S-4S Lixx batteries  •

• Touchscreen Graphics LCD Display 

• 5 User Profile Memories

• 25-Year Warranty 

• Multi-Protection-System

Please read the following instructions carefully before you start using your charger. This user guide contains important 

notes for the installation, the safety, the use and the maintenance of this product. Thus protecting yourself and avoid 

damages of the product.

Proceed according to the user guide in order to understand your charger better. Please take your time as you will have much 

more joy with your product if you know it exactly.

This user manual shall be kept in a safe place. If another customer is using this product, this manual has to be handed out 

together with it.

la00048

user guide - #41555

LRP electronic GmbH 

Wilhelm-Enssle-Str. 132-134

73630 Remshalden, Germany

[email protected]      www.LRP.cc

© lrP electronic gmbh 2010

Dimensions

[mm]

1585x172x68

Autostart Timer

yes, 0-99min

Weight

[g]

720

Cycle Mode

yes, adjustable

Input Voltage

[DC]

11-15V

User Profile Memory

5

Charging Capability LiPo/LiFePo

1 - 4 cells

Graphical Touchscreen LCD

yes, blue backlit

NiMH/NiCd

1 - 10cells

Acoustic Signal Type

Buzzer

Charge Current

[A]

0.1 - 12.0

Finish Melody

adjustable

Trickle Current

[A]

0 -0.55

Multi-Protection-System

yes

Delta Peak

[mV]

1 - 200

DC Input Connection

4.0mm connector

Integrated High-Performance Balancer yes, 2S - 4S

Output Connection

4.0mm jacket

Storage Charge Mode

yes

Brushless Motor Sensor Port

yes

Discharge Current

[A]

0.1 -20.0 (+ 35 Pulse)

RX Generator (ESC + Servo Check)

yes

Discharge 

Cut-Off Voltage

LiPo/LiFePo

2.0 - 4.2V/cell

Voltage Calibration Mode

yes

NiMH/NiCd

0.1- 1.3V/cell

USB Connection

yes

Specifications subject to change without notice.

Output Jacket:

 

connect battery to be charged to the 

4.0mm jacket, using supplied charge wires.

Caution: 

Be careful with correct polarity!

Balancer Connector:

 high-performance integra-

ted Lixx balancer for 2S to 4S packs using EHR balancing 

connector.

The 

Pulsar Touch

 comes with 5 pre-set user profiles, but you can also alter those and prepare 5 individual user profiles and 

even name them as you like. This means you can customize 5 personal charge profiles individually and store them for later 

use. The active profile P1 to P5 and it‘s name is indicated in the headline of the main menu.

User Profile

P1

P2

P3

P4

P5

CHARGE SETTINGS:

Chg Mode

LiPo

LiFe

LiPo

LiPo

Linear

Current

6.0A

6.0A

6.0A

2.0A

4.0A

Pack Volt

7.4V / 2S

6.6V / 2S

3.7V / 1S

11.1V / 3S

D-Peak

20mV

Trickle

Off

Safety Time

120min

120min

120min

180min

90min

40°C

40°C

40°C

40°C

55°C

DISCHARGE SETTINGS:

Current

20.0A

20.0A

20.0A

2.0A

10.0A

Pack Volt

7.4V / 2S

6.6V / 2S

3.7V / 1S

11.1V / 3S

Cutoff Volt

3.2V/C

2.2V/C

3.2V/C

3.2V/C

5.4V

Cut-Temp

60°C

60°C

60°C

60°C

70°C

OTHER SETTINGS:

Profile Name

2S-LiPo 6A/20A

2S-LiFe 6A/20A

1S-LiPo 6A/20A

3S-LiPo 2A/2A

Linear 4A/10A

Signal Min

1000

Signal Max

2000

Button Sound

On

Finish Sound

15sec

Finish Melody

1

LCD Contrast

7

Temp Scale

°C

The 

Pulsar Touch

 contains an integrated competition balancer for 2S to 4S LiPo- and LiFePo-batteries using EHR balancing 

connector. Please refer to drawing (also like that on charger) for correct polarity, basically minus (black wire) is always on the 

far right side of the plug as shown on drawing.

The balancer equalises the cells, during charge- and balance-function, which results in higher performance and higher cycle-

life.

Caution:

 Avoid incorrect connection as in the worst case this may result in damage to the battery and/or charger!

As known from LRP, the programme structure is logical and intuitive, therefore most users can familiarise with the usage and 

functions without even reading the manual, but it is obviously strongly recommended to read this manual in order to achieve 

maximum performance from the PulsarTouch and make best use of all of it‘s great features.
You can either use your finger or the included plastic pen to use the touchscreen, make sure you only use very light pressure 

to activate the functions as too high pressure may damage the display!

How to change the profile names? 

Keep headline pressed in main menu, this brings you into the function to alter the active profiles name.

press arrow to scroll to the 

„right“ (e.g. next function)

press arrow to scroll to 

the  „leftt“  (e.g.  previ

-

ous function)

Press briefly to jump to next profile (P1 > P2 > P3 > P4 > P5 > P1 ...). 

Keep pressed to enter „Profile Name“ menu, which allows renaming of the choosen profile (see below).

press  „SETUP“  to  change  the  settings  of 

this  function  (in  this  case  the  function  is 

LINEAR CHARGE).

The  logo  (LINEAR  CHARGE  in  this  case)  indicates 

which function is pre-selected.

Press „START“ or center symbol to start the function.

Temperature Sensor

 (optional)

: connect the 

optional temperature probe to measure battery tempe

-

rature.

USB Connection:

 

connect to PCB using the sup-

plied  USB-cable.  To  be  used  for  upcoming  firmware 

updates and PC software.

Brushless Motor Sensor Port:

 a fantastic fea-

ture which allows you to check your brushless motors 

sensors  and  even  measure  motor  rpm!  In  combination 

with the built-in receiver simulator port.

RX Simulator Port:

 you can even check speed-

controls and servo‘s for correct function!

15A Fuse:

 input fuse for protection, only replace with ano-

ther 15A fuse (blue colored housing) and no other types as 

these would not offer protection or correct function!

Connection Example 2S:

Bl

ac

k

Min

us

Adjusting the settings and hoping through multi-page menu:

Hidden buttons and how to make them visible again?

To allow more clean screen and more useful information, the  buttons will be hidden during many active functions. Simply 

touching the screen anywhere will make the buttons visible again. After a short while of no use of the screen, the buttons 

will hide again automatically.

Buttons Hidden: 

 

Buttons visible again (after briefly touching screen anywhere):

as  [1/2]  and  [2/2]  indicate 

in headline, there is a multi-

page menu with more then 

one  screen.  You  can  hop 

through the pages by pres

-

sing „NEXT“ button.

after accessing the menu with „SE

-

TUP“ you can select the value which 

you may access that value directly 

by pressing with your finger or pen 

or by pressing „SET“ button. 

Once this line is shown inversed 

(black  background),  you  can  then 

change that value using the up/down 

arrown keys.

You  may  leave  the  „SETUP“  menu 

again at any time, and the current 

values will be stored, by pressing X 

in upper/right corner

Tip

: You can always reset to above factory default settings under „CONFIG“ function (see separate box).

indicates which 

character in head-

line you have se-

lected for changing

You can change the name in several ways, pick the method you feel most 

comfortable with.

1. straight indicate/write by touching the characters one after the other.
2. hop through the characters by using the right key and confirm the se

-

lected character by using the „√“ key.

You confirm and leave this setting by either pressing „X“ symbol in upper 

right corner or by pressing „OK“ key.

indicates new character 

you have selected.

How to adjust the current on the fly?

As known by LRP, the 

Pulsar Touch‘s

 current (charge or discharge) can be adjusted during use. Touch the current value on 

the screen, the characters will become inverse (black background) and then use the up/down arrow keys to adjust the current 

to your desired value without interrupting the active process. 

Important:

 This change is not saved in memory, the next time you use this function the settings from the memory will be 

used.

Touch current, characters will be

-

come inverse (black background)-
Now  use  up/down  arrow  keys 

to adjust current to your desired 

value.

Bl

ac

k

Min

us

Bl

ac

k

Min

us

Ce

ll 1

Ce

ll 1

Ce

ll 1

Ce

ll 2

Ce

ll 2

Ce

ll 2

Ce

ll 3

Ce

ll 3

Ce

ll 4

Input Connection

 (backside of charger, no picture)

:

 

connect your Pulsar Touch to a suitable DC powersupply with 

11-15V output voltage and a minimum of 12.0A output current. 

Caution: 

Be careful with correct polarity!

Отзывы: