Rev.: 13.01.2014
16
ZelFlex Z4P
InstRUctIons FoR Use
7
USE oF ZELFLEX Z4P
7.1
Process of inserting the stencil
Remove the protective holding bars side by side: press down, slide to the left and lift
them.
Before tensioning the stencil, always CHECK your system’s air supply characteristics!
Use of Air supply unit (available as an option) with 5 μm air filter and water separator
is advised.
Make sure there is no pressure in the frame.
1.
Always use dry and clean air only! Particles and humidity can damage the frame or
the air connector.
LPKF recommends:
ZelFlex Z4P
Stencil thickness
80 μm
100 μm
120 μm or thicker
Recommended air supply
4,5 bar
5,0 bar
6,0 bar
ZelFlex Z4P Slim
Stencil thickness
80 μm
100 μm
120 μm or thicker
Recommended air supply
5,0 bar
5,5 bar
6,0 bar
Содержание ZelFlex Z4P
Страница 1: ...USER MANUAL Pneumatic 4 side quick release stretching frame LPKF ZelFlex Z4P ...
Страница 2: ......
Страница 24: ...Rev 13 01 2014 24 ZelFlex Z4P maintenance Notes ...