background image

1949319   

V1.4 

June 2019 

 

Clevertest and Clevertest Plus 

 

Refer to the supplementary operation guide supplied with the Product.

 

 

 

After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid 
Green or Red flashing for a period up to 2 minutes. 

 
Zoneworks and DATA Monitored Options

 

Supalites  with  part  numbers 

–ZW

  and  -DATA 

are  fitted  with  Zoneworks  communications 

modules (nodes).These fittings are monitored using either Powerline Carrier Technology that 
utilising the power cable to provide data communication or a dedicated data cable to/from data 
routers  installed  on  a  dedicated  data  trunk  connected  to  a  central  Server  (can  also  be 
connected via Ethernet/Internet/Fibre). Zoneworks software on the server is used to monitor, 
coordinate  testing  and  collate  test  data  from  each  fitting.  Zoneworks  Supalites  can  be 
commissioned by a single push of the test switch or scanning of the supplied barcode. The 
LED  Test  Switch  indicator  provides  a  multifunction  indication  of  the  status  of  the 

‘Supalite 

during testing and normal operation: 

State

 

LED Operation

 

Commissioned 

LED on Solid (GREEN) 

Un-commissioned 

LED flashes at 0.5Hz (0.5s GREEN, 0.5s Yellow) 

Emergency Light Test In 
Progress 

LED flashes at 3s On (Yellow) & 0.5s Off 

 
In the case of the DATA version a 2-

way “figure 8” cable and terminal block facilitates the 

connection to the DATA network via a multi-drop bus (daisy chain connection).  For further 
information of installation of a Zoneworks system, please refer to the Zoneworks Users 
Guide and Commissioning Guide (incl. DATA version)  

 

DALI EM Option

 

Supalites  with  part  numbers 

-DALI 

are  fitted  with  DALI  modules  (nodes)  that  facilitate 

connection and integration to 3

rd

 Party Lighting Control Systems.  Before installing the -DALI 

Supalite, please confirm that the Lighting Control System has the capability to monitor DALI 
Emergency Luminaires.  The Supalite will be addressed and configured into the control system 
by the Lighting Control System Commissioning Technicians and not Clevertronics.   

State

 

LED Operation

 

Commissioned/ Un-
commissioned 

LED on Solid (GREEN) 

Emergency Light Test in 
progress 

LED flashes at 1s On (Yellow) & 1s Off 

“IDENTIFY COMMAND” 

Fitting goes into emergency mode for 10 seconds 

 
A 2-

way “figure 8” cable and terminal block facilitates the connection to the DALI network OR 

a 5/6way “structured wiring system” lead and plug facilitating the power and DALI 
connection.  DALI connections are marked as Da Da.  

 
 

 
 
 

 
 
 

 
 

 
 
 

LP™ 

Supalite Weatherproof Emergency Luminaire 

With Remote Lamp Heads 

Installation & Maintenance Instruction Leaflet

 

D

esigned in Australia to comply with the 

requirements of AS2293.3: 2005 and AS CISPR15: 
2017. 

NOTE: Standard product codes with this symbol       are 
enabled with Clevertest Plus capability.  Please refer to the 
operation guide supplied with the product for details.

 

Victoria (Head Office & Manufacturing) 

195 Chesterville Rd 

Moorabbin VIC 3189  

Phone:

 +61 3 9559 2700  

Fax:

 +61 3 9559 2799 

 

News South Wales

 

Phone:

 +61 2 8805 6400 

Fax:

    +61 2 8805 6444

 

Queensland

  

Phone:

  +61 7 3442 9700 

Fax:

     +61 7 3442 9777 

 

South Australia/Northern Territory

  

Phone:

 +61 8 8301 8800 

Fax:

   +61 8 8351 8286 

 

Western Australia

  

Phone:

 +61 8 9248 3720 

Fax:

   +61 8 9248 3725 

 

New Zealand

 

Phone:

 +64 800 548 448 

 

Models:  

 CWFLED-xx-2IPREM-yy 

Testing:

 

 

 

Options: 

 

Manual Test  

xx = Blank 

 

Black 

yy = BLK 

Zoneworks 

xx = ZW 

 

 

 

Zoneworks 
DATA   

xx = DATA 

 

 

 

DALI 
Compatible      

xx = DALI 

 

 

 

Clevertest 

xx  =  CT 

(

NOTE:  Products  supplied  with  the  Clevertest  Plus  Symbol              are 

activated  with  Clevertest  PLUS  capability.  Please  refer  to the  operation guide 

supplied with the product for details). 

Spare Parts:  

1550290

 

BATT: LP 6.4V 3.2Ah.200mm lead.Stick.Brkt 

1100550  

WP Led Head, c/w Led's & Loom 

1100551  

WP Led Head, c/w Led's & Loom, Gland, 

BLK

 

CCPLED-WP-18V625C-CKIT 

LED Power Pack, 18V 625mA, IP Loom, LP 

Important:

 

 

It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before 
installation, ensure that the electricity supply has been switched off and isolated. Installation 
must be carried out in accordance with the relevant Australian and International Standards.

 

 

 

 

 

 

 