background image

12' AC Unswitched Cable  

Code: P2-80

#18/3 cable with IEC connector is supplied with
the Pro-light to extend its captive cable. 

Code: P1-80 

Original AC cable for 

pre-updated Pro-lights (pre-April 2003).

Optional Power Cables

To connect to international voltage or popular battery power sources,
the following adaptor cables are available from Lowel for updated (IEC)
Pro-lights (contact us for older models).

AC options

P2-801  12’ Pro Euro cable (IEC)

P2-802

12” Pro UK cable (IEC)

12 Volt battery

P2-82

1' 4-pin XLR Cable

P2-85

1' 12v Cigarette 

Lighter/CarAdaptor Cable

30 Volt battery

P2-81

1' 2-pin switched 30v Cable

Power Cables & Connectors

Female

Male

1'

Female

Male

1'

Male

Female

12'

Male

Female

12'

Female

Male

1'

The  Lowel  Pro-light  is  a  professional
lighting fixture. Read these instructions
and  lamp  manufacturer’s  warnings
before operating.

n

Not  for  house  hold  use,  use  only 

for

film, video or imaging purposes. 

n

Do not leave fixtures unattended.

n

Unplug fixtures when not in use.

n

The units use lamps of several 

different

voltages.  Make  certain  that  lamp  voltage
matches power source voltage. 

Example: never

connect a 120 volt lamp to a 220 volt source. 

n

Units  such  as  this  emit 

considerable

light and heat, and if not properly used, could
be dangerous. 

n

Lights  should  not  be  positioned

extremely close to people. Ultraviolet light ray
emissions can cause damage to the eyes and
reddening of the skin. The likelihood of either
occurring is increased with length of exposure,
focus intensity and proximity. Therefore, lights
should be kept away from people. 

n

Avoid aiming the light at, or placing 

too  close  to,  people,  delicate  objects  or 
flammable materials. 

n

Do not interfere with ventilation 

by covering the lights in any way.

n

For proper ventilation, do not tilt 

down beyond 45 degrees or operate sideways.

n

Do not operate Pro-lights upside-

down with lamps of more than 125 watts. 

n

Do not tilt Pro-light down 

if mounted on

top of a camera. Camera damage could result. 

n

Never touch hot parts only touch 

handles & knobs for light adjustments.

n

Do not touch Pro-light upper front 

end  knob  while  operating  the  light,  high 
temperature is present.

n

Do not use near standing water.

n

Avoid mounting lights directly over 

people  unless  secured  with  a  safety  cord 
or cable.

n

The  updated  Pro-light  (2003)  has 

an

IEC connector  for  its  integrated  AC  Cable.
However  older  Pro-lights  use  a  3  pin  Edison
fixed  power  cable  which  is  to  be  used 
only  with  the  Pro-light  and  not  as  a  general-
purpose extension cable.

n

Keep Pro-light power cable away 

from front housing when hot, to avoid damage.

n

If battery power is used, never store 

the light without first removing the power cable
from the power source.  

Lowel Pro-light Instructions

Warnings

Pro-light Technical Data

Lamp/Beam Data             

(Pro & i/id lamps are not interchangeable)

Performance

Slot & lock for
umbrella and
gel-frame

160° constant tension 
no-yoke tilting from 
stand-fitting. 

4.6” (11.7 cm)

3.

7”

 (

9.

cm

)

6.

7”

 (

17

 c

m

)

Front-end
comes off for
easy, no-tool
lamp change

Screw-in lock
for front-end

Focus
knob

Stand fitting
& locking
knob for 5/8”
stand tops

AC switch

Weight: 

Pro w/ 4' captive cable: 

1.3 lbs (590 g)

Pro w/ 4' cable & 12' 
extension cable: 

2 lbs (907 g)

Max. wattage: 

250

Max. amperage: 

8.3

Beam control: 

continuously variable

Fits on: 

5/8" (1.59 cm) studs

Materials: 

primarily aluminum 

and Ryton 

Cable: 

with extension 16' (4.88 m) 

#18/3. CE model with #18/2.

Switch: 

in-head

U.S. Patent: 

4777566

Feet

5

10

15

20

25

0

5

10

5

50

°

24

°

10

°

0

1.5

3

1.5

1.5

3

4.5

6

8

Meters

Flood
Spot
Super Spot

Beam Angles

with Clear Safety Glass

Foot Candles 

(Lux = foot candles x 10.8)

86

552

1139

23

143
302

11
61

135

7

34
80

4

22
47

With 120v, 200w, 3200°K, 
Osram FVL lamp

Lamp

Volts Watts

°K

Avg

F. C. (lux) 

at 10’ (3 m)

Code

Life

Flood

Spot

Focus Range Super Spot

FVL*

120

200

3200

100 hr

23 (250)

143 (1540)

6:1

302 (3260)

FSH

120

125

3200

100 hr

11 (115)

48 (515)

4.5:1

139 (1500)

GCC

12

100

3200

100 hr

12 (125)

58 (630) 

5:1

245 (2650)

JCV14.5V-50WC

12/14

50

3200

100 hr

6 (70)

28 (305)

4:1

125 (1350)

GLF/P44 ** 230

235

3200

100 hr

39 (420)

81 (880)

2:1

178 (1920)

* Replaces GCA as recommended lamp
** Only fits CE Pro-light, updated Pro-light (4/2003) & older Pro-lights with updated Front
Housing (iP2-18 )

Pro Lamp Replacement

Warning:

Always unplug unit before relamping. Fixture must be cool

before lamping. Lamps must be operated at their rated voltage. 
Avoid touching “glass” with bare fingers. Insert lamp carefully, 
to avoid breaking.

To change lamps
1

Turn focusing knob 

A

to spot position. 

2

Unscrew the small knob 

B

located on top of the front 
housing. Remove front assembly. 

3

Grasp porcelain socket of lamp 

C

and rock lamp gently from side 

to side while pulling straight out from fixture socket. 

4

To replace lamp, hold focusing knob in spot position and insert 
lamp into socket. 

Warning: 

Avoid touching the glass of the lamp 

with bare fingers. Make sure lamp is well seated in the socket. 
Improper insertion could result in arcing, which will shorten lamp 
and socket life. 

5

Replace the front housing and tighten the top knob. 

Warning: 

Compact filament lamps such as the GCA may fail if 

subject to vibration or shock while on. Turning the fixture off before 
moving or adjusting 
as well as operating 
the focus smoothly 
will help prevent 
lamp failure.

A

B

C

Yes