TG 60 / 268 

 

 

 

 

938240  Version 1.0 

Operator Instruction Manual 

Lovibond® Colour Measurement 

Содержание TG 60/268

Страница 1: ...1 TG 60 268 938240 Version 1 0 Operator Instruction Manual Lovibond Colour Measurement...

Страница 2: ...se charge the battery every two weeks if the instrument is not being used to avoid damaging the battery For the first three times please charge the battery fully to ensure it reaches its optimal state...

Страница 3: ...Turn on off 7 3 2 Calibration 8 3 3 Measurement 10 3 4 Connecting to PC 17 3 5 Printing 18 4 System Function Description 18 4 1 Data Management 18 4 2 Mode Selection 24 4 3 Mode Parameter 24 4 4 Angle...

Страница 4: ...function settings 6 QC software with powerful extending function 7 Input standard data manually easy to operate 8 High hardware configuration with multiple innovative technologies 9 Auto power off fun...

Страница 5: ...the measuring aperture and accessories After use please turn off Keep the instrument and calibration plate in the instrument case Users may not make any changes to the instrument without permission s...

Страница 6: ...l display a red light Fully charged will show green USB interface The instrument automatically recognizes the connection status The USB interface is used to transfer data to a PC It can also be used t...

Страница 7: ...rom two sides Figure 2 Separation Method 3 0 Operating Instruction 3 1 Turn on off Press the switch button for 3 seconds to turn on the instrument The LCD screen will display the boot logo After a few...

Страница 8: ...he main menu as shown in Figure 4 Select Calibrate to enter into Calibration mode as shown in Figure 5 OK Back Note The single angle gloss meter does not have this selection option The substitute opti...

Страница 9: ...Environmental factors will have an effect on the gloss value of the standard plate over time It is therefore recommended that it is returned to the factory or a qualified local National Institute of M...

Страница 10: ...ved automatically each time This data can be used as the standard in Statistic Mode It can display 5 sets of test data simultaneously Statistical Mode This provides a statistical evaluation and can me...

Страница 11: ...60 and 85 These can be selected by clicking Mode in the Main Menu or the icon to enter the interface as shown in Figure 7 Note The single angle gloss meter does not have this option Figure 7 Angle Se...

Страница 12: ...1 T005 are the numbers of the five measurements T102316 is the default name of the measured record It is made up from T month day hour so T102316 would represent a basic record measured on October 23...

Страница 13: ...nt measurement is under angle 60 The last record 66 3 in yellow is the current test data Click Menu in the lower right corner to enter the main menu interface 2 Multi angle measurement in Basic Mode w...

Страница 14: ...hortcut key for angle selection Note not available on the single gloss meter 6 6 The first 6 means the 6th measurement has been taken The second 6 means the statistical measurement time is 6 see secti...

Страница 15: ...the tolerance range Fail means the sample is not within the tolerance range please see section 4 5 for Tolerance Setting On completion of the current measurement the record can be deleted by selectin...

Страница 16: ...s C006 is the current measurement number which begins with the letter C The icon is a shortcut key for angle selection Note not available for the single angle gloss meter C102316 is a default name for...

Страница 17: ...ollow the instructions to connect the instrument to a PC Use the USB cable to connect the instrument to the PC first Click OK the instrument will start Communicating It is then possible to control the...

Страница 18: ...4 System Function Description 4 1 Data Management In the Main Menu select Data to view the data management screen as shown in Figure 16 Data management is mainly for checking and operating the records...

Страница 19: ...1 Check Basic Record There are 5 records displayed on the screen When angle 60 is selected the view will be per Figure 18 When all three angles 20 60 85 are selected the view will be per Figure 19 16...

Страница 20: ...gure 21 Select Operate to edit the last record Delete Record Select Delete Record a warning box will appear as shown in Figure 22 Click OK to delete the selected record Click Back to prevent deletion...

Страница 21: ...t Standard Entering to transfer the selected record to a standard record for statistic measurement Search Users can search the record by Search Index and Search Name Edit Name Figure 22 Deletion Warni...

Страница 22: ...ay just the one record as shown in Figure 24 When the 20 60 and 85 angles are selected the view will be per Figure 25 Click the record name S102316 to modify it per above Figure 24 Single Angle Measur...

Страница 23: ...e refer to part 2 of this section 4 1 2 Delete Record Click Delete Record As shown in Figure 27 there are three modes Delete Basic Record Delete Statistical Record and Delete Continuous Record Figure...

Страница 24: ...eters as shown in Figure 29 4 3 1 Average Measurement in Basic Mode This is an additional functional in Basic Mode Select Basic Mode Average to set the measurement times as shown in Figure 30 The numb...

Страница 25: ...in this mode All data will be saved in the basic record 4 3 2 Statistical Mode Parameter Users can set measurement times difference switch select standard and input standard Figure 31 Multi angle Meas...

Страница 26: ...When the difference switch is not activated the statistic measurement only evaluates the average value maximum value and minimum value It will not show the comparative function and deviation of the sa...

Страница 27: ...k 4 Input Standard It is possible to input data from a new basic record data as the standard of statistical mode This new record will automatically be saved in the basic record database Select Input S...

Страница 28: ...28 4 3 3 Continuous Mode Parameter There are two functions Measurement Times and Interval Time as shown in Figures 36 and 37 Figure 35 Input Standard Figure 36 Sub Menu of Continuous Mode Parameter...

Страница 29: ...lerance Settings Select Tolerance as shown in Figure 38 to define the tolerance between the standard against which the statistical data can be compared If the deviation to the standard is within the t...

Страница 30: ...or Left Handed Operation Screen Brightness As required Buzzer Switch On Off for sound when measuring Restore Factory Settings2 1 Note the instrument will turn off one minute after the backlight goes o...

Страница 31: ...irection Ensure there are no tiny particles or sundries on the cloth Clean the plate before calibration to ensure accuracy of measurements Note Do not use acetone solvent 3 In order to ensure the accu...

Страница 32: ...nsion L W H 160mm 75mm 90mm Weight 350g Battery 3200mAh Li ion Battery 10000 times within 8 hours Display TFT 3 5inch touch screen resolution 320 480 Interface USB RS 232 Storage Basic mode 1000 Stati...

Страница 33: ...00 Selangor D E MALAYSIA Tel 60 0 3 3325 2285 6 Fax 60 0 3 3325 2287 Email lovibond asia tintometer com Switzerland Tintometer AG Hauptstra e 2 5212 Hausen AG Switzerland Tel 41 0 56 4422829 Fax 41 0...

Страница 34: ...34...