background image

Translation of the original instructions

Installation and operating instructions

ELECTRIC FRYERS FOR

PROFESSIONAL USE

F18-94ETX F2/18-98ETX F25-94ETX F2/25-98ETX

F13T-94ETX F2/13T-98ETX

F2/8-94ETX F2/8T-94ETX

Model LIBR.ISTR.FX 90E POT

Code 563016404

Review 1

Edition date 17/01/2020

Language English

LOTUS S.p.A.

Via Calmaor, 46

31020 San Vendemiano

+39 0438 778020

+39 0438 778277

Содержание F13T-94ETX

Страница 1: ...FRYERS FOR PROFESSIONAL USE F18 94ETX F2 18 98ETX F25 94ETX F2 25 98ETX F13T 94ETX F2 13T 98ETX F2 8 94ETX F2 8T 94ETX Model LIBR ISTR FX 90E POT Code 563016404 Review 1 Edition date 17 01 2020 Langu...

Страница 2: ...on waste electrical and electronic equipment 11 2 3 Technical data table 11 3 INSTALLATION 12 3 1 Delivery checks 12 3 2 Removing the packaging 12 3 3 Mechanical installation 12 3 4 Electrical gas co...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 9E A Data Plate B Electrical connection...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 F T A Data Plate B Electrical connection...

Страница 5: ...ol knob to zero but the system remains operational until the problem that caused the intervention is resolved Contacts 80 and 81 are provided to enable the fryer to be controlled from a remote locatio...

Страница 6: ...tions 6 WIRING DIAGRAM A 1 Cicada 2 Switch 3 Microswitch 4 Power supply terminal board 5 Heating element 6 Resistance voltage drop 7 White indicator light 8 Red indicator light 9 Green indicator light...

Страница 7: ...original instructions 7 Electrical technical data table MODEL WIRING DIAGRAMS WIRING DIAGRAMS F18 94ETX A F2 18 98ETX A A F25 94ETX A F2 25 98ETX A A F13T 94ETX A F2 13T 98ETX A F2 8 94ETX A A F2 8T...

Страница 8: ...INTRODUCTION Translation of the original instructions 8 1 3 Fixing feet...

Страница 9: ...INTRODUCTION Translation of the original instructions 9 1 4 Example installation of the appliance...

Страница 10: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be he...

Страница 11: ...se provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical technical data table F S90EX MODEL DIMENSIONS POWER SUPPLY MAXIMUM POWER kW MAXIMUM...

Страница 12: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Страница 13: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Страница 14: ...leaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the...

Страница 15: ...at during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain coc...

Страница 16: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Страница 17: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Страница 18: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...