background image

Translation of the original instructions

Installation and operating instructions

PROFESSIONAL GAS FULL-PLATE

COOKER

TP-1110G TPF-1110G

Model LIBR.ISTR.TP110G

Code 5630515A0

Review 1

Edition date 07/06/2022

Language English

LOTUS S.p.A.

Via Calmaor, 46

31020 San Vendemiano

+39 0438 778020

+39 0438 778277

Содержание 5630515A0

Страница 1: ...tion and operating instructions PROFESSIONAL GAS FULL PLATE COOKER TP 1110G TPF 1110G Model LIBR ISTR TP110G Code 5630515A0 Review 1 Edition date 07 06 2022 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ...11 3 4 Electrical gas connections 11 4 BURNERS TECHNICAL DATA TABLE ITGB 15 4 1 Burners technical data table 15 6 INSTRUCTIONS FOR USE 16 6 1 General information 16 6 2 Lighting and adjusting the full plate 16 6 3 Starting the main burner and adjusting the temperature 16 6 4 Switching the main burner off 17 6 5 Turning the appliance off 17 6 6 Lighting and regulating gas oven burner 17 7 MAINTENAN...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 TP 1110G A Data Plate C Gas connection ...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 TPF 1110G A Data Plate C Gas connection ...

Страница 5: ...RODUCTION Translation of the original instructions 5 1 2 Components FIG B 1 Flame open by pass 2 Oven by pass FIG F Oven pilot 1 Pilot light nozzle 2 Ignition spark plug 3 Extends drainage 4 Pilot bracket ...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 FIG E 1 Oven injector 2 Oven air regulation FIG G Burner air adjustment ...

Страница 7: ...INTRODUCTION Translation of the original instructions 7 FIG I 1 Injector 2 Pilot ...

Страница 8: ...INTRODUCTION Translation of the original instructions 8 1 3 Example installation of the appliance ...

Страница 9: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Страница 10: ...the original instructions 10 2 2 Technical data table Technical data table TP S110G MODEL DIMENSIONS BURNER TP 12kW BURNER OVEN 10kW TOTAL POWER kW GAS FITTING ISO 7 1 TP 1110G 100x110x90h 1 12 R1 2GM TPF 1110G 100x110x90h 1 1 22 R1 2GM ...

Страница 11: ... not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The ...

Страница 12: ...se a naked flame but substances that do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indicated on the data plate see attachment Note The year of construction of the appliance is indicated under N on the data plate The first 2 digits indicate the year of ...

Страница 13: ...e of gas must be performed by a specialist technician The nozzles for the various types of gas are contained in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must discharge combustion products into appropriate hoods or similar devices connected to an efficien...

Страница 14: ...point 4 3 of the UNI CIG 8723 standard Resetting the gas supply to the appliance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The outlet section of the exhaust pipes for combustion products must be placed within the perimeter in relation to the hood itself ...

Страница 15: ...ar 9 45 kWh m3st G20 METHANE H 20 mbar Burner TP max 12 kW min 7 kW Burner injector 1 100 mm 165 165 260 Minimum adjustment 1 100 mm 130 130 130 Pilot injector 1 100 mm 19 19 27 Consumption kg h 0 946 kg h 0 932 m3 st h 1 27 Oven burner max 10 kW min 3 5 kW Burner injector 1 100 mm 155 155 245 Minimum adjustment 1 100 mm 100 100 adjustable Pilot injector 1 100 mm 19 19 27 Consumption kg h 0 789 kg...

Страница 16: ...alding RISK OF BURNS Do not touch hot surfaces floor with your hands or other parts of the body to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation 6 2 Lighting and adjusting the full plate The corresponding burner marked on the index is indicated above each knob on the fron...

Страница 17: ...o switch ON turn the knob to the left from the 0 position into the position hold the knob pressed and activate the button with the symbol until the pilot lights up Ignition of the flame can be checked through the inspection hole on the bottom of the oven Note The flame might go out in which case the procedure must be repeated Set the knob to the desired temperature position Turn the knob into posi...

Страница 18: ...equipment it is advisable to check the following at least once a year possibly increasing the frequency depending on the degree of use The status of connections especially on the terminal board and the power supply cable as well as the status of the gas connections The operating condition of the various components perform a functional test For appliances fitted with rotary resistances remove the h...

Страница 19: ... To replace such parts proceed as follows GAS TAP after disassembling the front panel unscrew the gas connection screw couplings remove the coupling replace the faulty parts and install the new ones in sequence THERMOCOUPLE unscrew the pilot burner coupling unscrew the gas tap coupling in the same way and replace the element SPARK PLUG unscrew the coupling remove the damaged one and replace it Cau...

Страница 20: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Отзывы: