background image

Translation of the original instructions

Installation and operating instructions

GAS FRYERS FOR

PROFESSIONAL USE

F13-554G

Model LIBR.ISTR.F110G

Code 5630507A0

Review 1

Edition date 26/05/2022

Language English

LOTUS S.p.A.

Via Calmaor, 46

31020 San Vendemiano

+39 0438 778020

+39 0438 778277

Содержание 5630507A0

Страница 1: ...nstallation and operating instructions GAS FRYERS FOR PROFESSIONAL USE F13 554G Model LIBR ISTR F110G Code 5630507A0 Review 1 Edition date 26 05 2022 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ... 4 Electrical gas connections 9 4 BURNERS TECHNICAL DATA TABLE ITGB 13 4 1 Burners technical data table 13 6 INSTRUCTIONS FOR USE 14 6 1 General information 14 6 2 Switching the pilot burner on 14 6 3 Starting the main burner and adjusting the temperature 14 6 4 Switching the main burner off 14 6 5 Switching the appliance off 15 6 6 Safety thermostat 15 6 7 Emptying the tank 15 7 MAINTENANCE 16 7 ...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F13 554G A Data Plate C Gas connection ...

Страница 4: ...n of the original instructions 4 1 2 Components FIG A 1 Gas inlet 2 Ramp 3 Injector 4 Burner 5 Safety thermostat 6 Air adjustment 7 Knob 8 Extends drainage 9 Pilot 10 Ignition spark plug 11 Oil drain 12 Piezoelectric 13 Valve ...

Страница 5: ...INTRODUCTION Translation of the original instructions 5 FIG C A Piezoelectric FIG D 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug FIG E Burner air adjustment ...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 1 3 Example installation of the appliance ...

Страница 7: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Страница 8: ...MATION Translation of the original instructions 8 2 2 Technical data table Technical data table F13 554G MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW TANK CAPACITY lt F13 554G 40x55x90h R GM 10 5 13 ...

Страница 9: ...install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The appli...

Страница 10: ...hat do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indicated on the data plate see attachment Note The year of construction of the appliance is indicated under N on the data plate The first 2 digits indicate the year of construction THERMAL OUTPUT CONTR...

Страница 11: ...ined in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must discharge combustion products into appropriate hoods or similar devices connected to an efficient fume stack or directly to the outside Natural evacuation Fig 1 If this is not possible using an air su...

Страница 12: ...liance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The outlet section of the exhaust pipes for combustion products must be placed within the perimeter in relation to the hood itself 1 Windproof fume stack fig 3 Extractor hood fig 4 2 Servo system B11 type ...

Страница 13: ...rs technical data table Technical data table Burner F S110G 12 68 kWh KG G30 BUTANE 30 mbar 12 87 kWh KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar F13 554G Burner injector 1 100 mm 3 x 93 3 x 93 3 x 148 Pilot injector 1 100 mm 30 30 51 Consumption kg h 0 828 kg h 0 816 m st h 1 111 Primary air H mm max max max ...

Страница 14: ...e body to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 6 2 Switching the pilot burner on Press and turn the valve knob fig A pos 7 into star position Keep the knob pressed then press the piezo button repeatedly The fl...

Страница 15: ...em occurs again call the assistance service so that the causes can be eliminated Warning If using the fryer with products other than oil lard for example that have considerable thermal inertia it is necessary to set the thermostat to a low value e g 110 C during the first cycle not starting cold The thermostat can be set to the maximum only after the entire mass has melted 6 7 Emptying the tank Th...

Страница 16: ...ated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing the frequency depending on the degree of use The status of connections especially on the terminal board and the power supply cable as well as the status of the gas connections The operating condition ...

Страница 17: ...rts proceed as follows VALVE fig A pos 13 after disassembling the front panel unscrew the gas connection screw couplings and extract the valve bulb then replace the faulty parts and install the new ones in sequence THERMOCOUPLE fig D pos 3 unscrew the pilot burner coupling unscrew the valve coupling in the same way and replace the element IGNITION SPARK PLUG fig D pos 4 unscrew the coupling remove...

Страница 18: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Отзывы: