background image

Translation of the original instructions

Installation and operating instructions

ELECTRIC FRY-TOP FOR

PROFESSIONAL USE

FT…-558ETS FT…-118ETS

Model LIBR.ISTR.FT110E

Code 5630505A0

Review 1

Edition date 17/05/2022

Language English

LOTUS S.p.A.

Via Calmaor, 46

31020 San Vendemiano

+39 0438 778020

+39 0438 778277

Содержание 5630505A0

Страница 1: ...on and operating instructions ELECTRIC FRY TOP FOR PROFESSIONAL USE FT 558ETS FT 118ETS Model LIBR ISTR FT110E Code 5630505A0 Review 1 Edition date 17 05 2022 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ...trical and electronic equipment 8 2 3 Technical data table 8 3 INSTALLATION 9 3 1 Delivery checks 9 3 2 Removing the packaging 9 3 3 Mechanical installation 9 3 4 Electrical gas connections 9 4 INSTRUCTIONS FOR USE 11 4 1 General information 11 4 2 Turning the appliance on off 11 4 3 Emptying the container 11 4 4 Observations and advice 11 4 5 Safety thermostat 12 5 MAINTENANCE 13 5 1 Routine 13 5...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FT 558ETS A Data Plate B Electrical connection ...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 FT 118ETS A Data Plate B Electrical connection ...

Страница 5: ...DUCTION Translation of the original instructions 5 WIRING DIAGRAM B 1 Switch 2 Power supply terminal board 3 Heating elements 4 White indicator light 5 Green indicator light 6 Thermostat 7 Safety thermostat ...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 1 2 Example installation of the appliance ...

Страница 7: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Страница 8: ...n the environment and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data t...

Страница 9: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The a...

Страница 10: ... of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them secu...

Страница 11: ...fter switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the desired position between 50 and 300 C the white and green indicator lights will turn on The green indicator light indicates that the appliance is powered...

Страница 12: ...mostat The appliance is equipped with a safety thermostat that interrupts the electrical circuit if the temperature of the hotplate exceeds the maximum preset value 420 If this happens the appliance can be restored by pressing the red button on the safety thermostat If the problem occurs again call the service department which will remove the causes ...

Страница 13: ...ce and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personnel When replacing the electrical components of the machine and the electrical panels scrupulously follow the technical characteristics for the replacement component indicated on the component itself T...

Страница 14: ...al connections and proceed with replacement The thermostat and switch are fastened together by a metal bracket HEATING ELEMENT remove the panel and remove the wires connecting the heating element From the bottom unscrew the housing that contains the heating element and once removed make the replacement Caution WHAT TO DO IN THE EVENT OF FAULTS Close the gas connection cock and or switch off the po...

Страница 15: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Отзывы: