5.2 -Temperature control

- This heater as a temperature controler to avoid overheating problems, ie, when the outlet
water temperature reaches high values, the heater is automatically switched off and there is no
heating water.
- The controller is reset atomatically .
- To place the product back in operation, close the hot water faucet / tap and then re-open it .

- If the problem continues, do not use it , turn off the product close the valve and get in
contact an authorized technical assitance.

6 - Maintenance

-

-

IMPORTANT:

Whenever you make any maintenance at your heater, the
removal of the batteries from the compartment is recommen-
ded to avoid unexpected product activation .

- For a proper operation and extended life of the product,

proceded periodic reviews (between 1 and 2 years) at the
product, through the authorized technical assitance.
To clean the external cover use a damp cloth and mild soap, do
not use chemical products (gasoline, alchool, thinners, etc.)
powders or abrasive products. - When replacing parts, always
use only original Lorenzetti spare parts.
Clean the filter at water inlet of the product every 6 months or
shorter periods, if necessary proceed as follows:
1.- Close the cold water valve of the product (Pic 1)
2.- Open a hot water tap/faucet to drain the water stored inside
the product and / o pipe.
3.- Remove the water inlet connection of the product.Taking care to place a bucket just below
the product in order to receive the waste heater that eventually may still be inside product
and/or pipeline, avoiding wetting the area around the product.
4.- With the help of an adequated tool( screwdriver, for axample), remove the filter screen
metal placed inside duct inlet water of the product (Pic 7)
5.- Clean the filter, eliminating completely eliminate on the surface any dirt and debris.
6.- Replace the filter on your site connection and water inlet product, certify if the connection
is well fastened to prevent water leakage.

07

7.- Close the hot water faucet previously opened and open the cold water valve of the pro-
duct*(pic1).

08

*

If the pressurized hydraulic networks, precaution air removal of the pipe then after cleaning

the filter. If in doubt, contact a especialized person

6.1 - Danger of Freezing

If under the local weather where the product is installed there is a possibility that the tempera-
ture reaches values below zero degrees centrigrade (OºC), the water from the product should
be drained to prevente irreversible damage at the product.

Orientative

drawing

inlet
filter

cold water

inlet

7

6.2 - Removing the front cover of the heater

To drain the water, close the cold
water valve supply and completely
drain the water from the product,
removing the relief and drain valve
(Pic 8) and also the connection of
output hot water of the heater.
- Take care to place a bucket just
below the heater to collect the
water drained from the product and
pipe, avoiding wetting the region
around the heater.
- After draining, replace relief and
drain valve and the output connec-
tion of hot water, making sure to
fasten properly to avoid water
leakage.

To Remove thr front cover of the
product, proceed as follows- (Pic. 9):

1. Remove the buttons “A”, “B” and
“C”, pulling them forward

2. Unscrew the two screws Philips at
the botton side of the front cover

3. Pull the cover forward and to then
up.

Obs.:

To replace the front cover

upside proceed to disasembling.

Procedure that should be

done by technician

Button “C”

Socket

Identification
product stickers

screws

Button“A”

Button “B”

gas inlet

cold water

inlet

8

hot water

inlet

Aliviate drain valve

Orientative drawing

ON

OFF

VER

ÃO

INVERNO

www.lorenzetti.com.br

(5511) 2065 7396/7

[email protected]

Lorenzetti S.A. Indústrias Brasileiras Eletrometalúrgicas

Av. Presidente Wilson, 1230 - CEP 03107-901

Mooca - São Paulo - SP - Brasil

C.N.P.J. 61.413.282/0001-43

09

9

10

This product should be connected to a water distribution mains compatible to its capacity, as
specified at item 8 (Technical Characteristics). It is not recommended to use the product for
other purposes than the above.

- An installation that does not meet required standards may cause damages. Lorenzetti is

not responsible for any damages and losses caused by inadequate installation.

- Do not touch the outlet area of the exhaust of combustion gases (chimney and nearby

areas) due to the high temperatures reached under normal conditions of usage that can
cause burns.

- Do not expose the product to cooking steam.
- Do not wash the product, install it or exposed to the weather without adequate protection

against  dust, water or other incidence of excess liquid and air flow (windy place).

- Do not place anything onto the product.
- When opening the package, make sure about the perfect state of the product.
- In case of doubt, do not use the product and contact the authorized technical assistance.
- Do not throw to the environment any packaging, plastic bags, styrofoam etc.. and not let

the children reach them as they are potential sources of accidents.

After installing the product to remove the label on the front face of the product (Conpet
Tag / Inmetro).

- We do not advise the operation of this equipment by children, the elderly and phisical
impaired without any supervision.

If gas can be smelt where the product is installed, do no activate circuit breakers, phone or any
other euipment that can spark.
Have windows and doors open immediately to renew local air. Close the gas central valve (in the
counter) or in the gas receptable and request the presence of your distributer. In case nobody is
present at home, close the central gas valve. Acoording to technic standards in force, this product
can be only installed and work in and terminals type T or «Chinese Hat» only in places protected
against the wind that comes from the outside and inside of the environment. Pieces for this
product can be replaced only by your distributor. This equipment is destined for domestical use
(Hygienization).

9 - Special care

8-Technical Characteristics

11

*Subjetc to change without notice
**Values minimum flow and pressure depend on the position

that fits the "B" (fig. 6).Values

*** Minimum operating pressure measured according to
NBR 8130 no load loss (this value may vary according

to the hydraulic system of residen

ce.)

GN

G.L.P.

2,26
------

1,74

----

3,02
------

2,34

------

Tecnical Characteristics*

Power consuption in normal conditions
(15º C e 101,33 kPa (760 mmHg))

(kcal/min)

(kW)

Efficiency about P.C.S.

(%)

(s)

Time of ignition of safety valve to start

(mca)

(m³/h)

Water maximum pressure

Gas consuption at the standard conditions
15°C e 101,33 kPa (760 mmHg)

(kg/h)

Minimum conditions for a ignition **

26,0
84

1,0

GN GLP

2,5 a 7,5

87

342,57

24,6

GN GLP

Heater connections

(pol.)

Inlet gas pressure of the product

(mmca)

Batteries for the ignition ( D type)

(V)

Dimensions
Height (A)

Diameter of de chimney ( C )

Gross weWeight
NetWeight

(mm)

(mm)

(kg)
(kg)

200

280

1,5

½” BSP

610

125

12,50

14,20

479
33,4
83,0

2,5 a 7,0

83,0

461
32,2

200

280

610

125

12,5

14,20

Flow capacity by temperatura elevation 20ºC
standard conditions (15°C e 101,33 kPa (760 mmHg)

(l/min)

flow

flow

pressure

(l/min)

(mca)

1,5 a 3,5

1,0 a 2,0

80

hidraulic

gás

LZ - 1600 N

LZ - 2000

15,5

15,0

20,0

19,0

***

Ø C

D

B

E

inverno

verão

gás

mín.

máx.

F

A

água

mín.

máx.

Width(D)
Depth (E)

(mm)
(mm)

350

350

190

190

342,57

02

03

3.2- Water connection

hose hot

water

cold water

valve

gas valve

outlet  gases

clamp

1

Note: The tube, clamp, register,

water and gases hose does nor supplier

**

These products allow the gas exchange rate for NG for LPG and LPG for NG.

VERÃO

INVERNO

3.3- Combustion gas exhaustion

For combustion gas exhaustion proceed with the installation following the local lows procedures.
The gas heater are provided with connection to the exhaust gas duct and must have a direct connecti-
on to the individual or collective chimney (pic. 3)
The interconnection of the product to the external environment need to be accomplished through
individual or collective chimney, a pipeline made by appropirate materials, and resistant against
weather , normal mechanical stress, heat and other environment conditions where the product is
installed.
The exhaustion gas duct should not have its diameter reduced to lower measures than specified at
item 8 of this manual (chimney of the diameter)

04

05

For the ventilation at the installation point, check your local standards requeriments.
It is forbidden by its danger to operation of vacuum cleaners, and fireplaces similiar in the
same place where the products installed.
The environment where the product is installed must be provided regular input of oxygen to
ventlitation and shall have:
1) Permanents openings at the wall to communicating with the outside.
2.Ventilation duct (individual or collective) in case where there is such a need .

3.4- Environment ventilation

Model for the installation of the product in a adequate environment:

Atention: For your safety, in case the product is being installed to replace an exis-
ting one in the interior of the bathroom or kitchen, check if the environment is
compliance with the local standards concerning to ventilation, gas exhaustion, as
well as special procedures described in item 9 of this manual.

4- Batteries installation

The two batteries of 1.5V (batteries size big type
D ), must be positioned in the compartment
located in the button part of the product (fig. 5).
The batteries are not provied with the product.
Observ the batteries polarity. Use a alkaline
batteries. In case the batteries are no being used,
at long period of time, remove them.
Batteries should be replaced periodically to
avoid is no ignition problems due to lack of
changing device (see item 7)

06

5- Operation

The gas heaters are appliances supplies the instant hot water.

Built-in an electronic circuit powered with 3V (2 batteries AA size - D type ), which ignites auto-

matically the burner always the faucet/ tap/valve hot water is open.

The hot water supply should be made through tap / record specific for this purpose.
Opening the tap, the main burner of the heater turns on and heats the water that runs
through a coil.

The water gets heat through paassing inside a coil. The lightining control and flame

opresence is made by an electronic system

5.1 - Using your equipment

The water temperature control can be done at three different ways.

Turning it clockwise, you get more gas.Turning it counter clockwise, you get less

gas, consequently, higher or lower temperature of hot water

For comfort and adjusting option, this button allows more precise control of

hot water temperature . At the winter position is higher heating capacity and at summer
position lower heating capacity. Using this control at the summer position is suitable for
warmer days

- Turning it counterclockwise, you get increased water supply, turning

clockwise is obtained consequently reduced water supply, higher or lower temperature hot
water.

You can control the temperature ( high water flow, means lower temperature or vice versa).

In the case of mixer usage , open to hot water and then gradually open the cold water faucet ,
until reaching the desired water temperature. In order to save gas, just use the heater with gas
control button at the intermidiate position or minimum (depending on the weather season).

Through the gas control buttons

Button C

By using the mixer or control the flow of hot water at the point of use. (through the

main register)

1)

.

Button A

Button B

2)

-

-

3)

With the button iat OFF position, the heater keeps

the burners disconnected and does nor promote
water heating. To re-heat the water, just set the
button at ON position.

Through the ON/OFF button , located on

the botton position at layer of the heater.

- For long periods without usage,

close the gas lo

g.

A - Button gas flow control
B - Button winter/summer
C- Button water flow control

Fleme

Visor

Controls

Buttons

ON/OFF

Button

inverno

verão

gás

mín.

máx.

Liga

Desl.

água

mín.

máx.

inverno

verão

GAS

mín.

máx.

WATER

mín.

máx.

2

Gás

cold

water

hot

water

VERÃO

INVERNO

3

Duct

air inlet

deflector

VERÃ

O

INVERNO

1- Presentation

2- Atention

INSTRUCTION AND

INSTALLATION MANUAL

INSTANTANEOUS

GAS WATER HEATER

LZ - 1600 N

LZ - 2000

- You have adquired Gas water Heater, developed to provide hot water without electrical power
consuption. Practival and economical, with automatic activation and pilot flame, to attend your
needs with greater safety and comfort.

- Please red carefully the installation instructions and operation before using de
product. Keep this manual for future references. The installation of this product
should be made by qualified personnel for your entire safety and product life
increasing. L
-The heaters are manufactured to operate by only one type of gas NG (natural gas)
or LPG ( liquefied petroleum gas)
- Its packaging on the lefts side of the layer(fig. 9) shows the identification of what
type of gas must be used. If in case any doubt consult your local dealer.

3.1- Gas Connection

-The installation of this product must cumply the standard of your country.
- For specials applications (central heatinf swimming pools,etc) consulting a
qualified technician.
-This manual recommend the installation by a qualified technician.
- The self-installation or by unqualified persons, made without proper care, can
offfer risks compormising prouduct performance.
- Caution: Do not install the producto exposed to the weather without adequa-
te protection against dust, impact of water or other liquids.

3- Instalation

- Verify if the type of gas supplied is compatible with the product adquired. Before to
the installation of the product please check the followings preocedures.

- Certificate that no residued and possibles losses in the gas pipe installation.

- Verifiy if the gas pressure supply is in accordance with the characteristics of the
product (Item 8 Technical characteristics). - Connecting the product to the gas pipe,
installing before the product a valve for blocking opening the gas supply (Pic 1)

-The gas heaters that operate with LPG gas, supply by
cylinders equiped with blocking and flow regulation deviced
must be interconnected to ensure safety conditions to the
people and the place where it is installed.
-The gas supply must be size acoording the flow required by
the product and be provided with all safety and controls
deviced needed.
- If the product is not used for a long pereiod of time, you
should shut off the main valve for safety reasons.
- Do not use gas pipes fro grounding wire the electrical
applianced.
-Check using some soap/detergents foam at all connections
to ensure there are not leakage.
- If necessary change the gas type supply, please request a
technician for proper conversion changing be performed on
the right way.

Provide the installation of a blocking valve in the water inlet point. Before starting the water connecti-
on of the device, open the blocking valve and let run the water to eliminate any air and any debris from
the pipe. (Pic.01)
Looking at the product, the cold water inlet is the right side , the hot water outlet is at the center side

and the gas inlet at the left side (Pic. 2). Be guided by markings on the bottom of
the product
Ensure that your intallations of hydraulic pipes are not being used as grounding
wire for any of your electrical devices or telephone, due to they are not recom-
mended for this purposes. Under these conditions severe damages are subject to
happen at the pipes and the product .

Check if all faucets and valves (for bathing ) closed
Confirm that the pressure of incoming water is under recommendation of the
product (item 8 -Technical Specifications). -

Use a proper treated water
The direct use of water from the mains depends on its constancy supply and adequate pressure
supplied. (see specifications table, item 8). The u

At the output for showers and mixer taps , install connections type

"Y". This ensures a good gperfor-

mance of the product and avoids eventual cuts of in the water supply .

If it is necessary to pressurize the network, perform it at two lines (hot and cold) in order to have a well

balance at water mixture.
For mixer faucet with monocontrol , make sure the pressures on the network (hot and cold water) are
well balanced

se out of these conditions can results to damage

of the product.
In case of the use of water from an artesian well, a craft well please make the proper phisi-
cal/chemical analisys of the waterand only used if it is under the correct standards of supply
network or properly weel treated for consumption.

5

Lig.

Desl.

Figura orientativa

SERVICE AREA

INLET AIR WITH

DEFLECTOR

GAS HEATER

4

UPPER VENTILATION

LOWER

VENTILATION

GAS HEATER

inverno

verão

água

gás

mín.

máx.

ºC

The combustion chamber

blades get dirty in a

short period of time

Gas smells

Smell of burnt gas

Ignition connects but

water does not heat

The heater disconnects

when the cold water is open.

The heater disconnects

during  the use

Reduction in the

volumen of hot water

The magnetic sensor is
locking the flow

Combustion output in poor
or dusty environment

Yellow flame

Excessive consumption of gas

Leakage at pipes net.

Evaporation of the resin

duct the chimney

Combustion Gas circuit obstructed

Lack of power

no gas

No power at the batteries

Dirt in the filter at the inlet water

Mixer "T" and imbalance

pressure of the network

Check the efficiency of the chimney and
duct output of the combustion gases.

Check the efficiency of the
chimney output of combustion gases

*

Verify the tube (test with soap foam)
Do not operate electrical switches or any
object that causes spark

Check the type of gas and clean the burner

Check and regulate it

Reducing the power of the

heater, open the windows *

Regulate the buttons  A and  B *

verify the supply *

Replace de batteries *

Close the main faucet personal

showers after the use*

Reduce the heater power

and open less cold water *

7-Eventualproblemsandrespectivesolutions.

Attention: The following checklist should be performed
by a qualified person. In case of doubts, please contact
distributor in your country .

*  This operations can be performed by the user

The pilot is connected

after the water is turned off

Main faucet of the
shower heads open.

Cleaning the filter  (verify  item 6)*

Replace the flow sensor

The pilot does not

connect even if
there are aparks

Control Device damaged

(gas valve)

no gas supply

Gas supply pressure inadequate

Air in the piping gas

Open the valve  checking for lack of gas *

Provide adequate gas pressure

Make the elimination of air

Solenoide stuck

Battery with low charge

Replace the batteries *

unlock solenoid

There is no spark

Batteries expired or bad contact

Ignition cable is loosen

Electric Circuit is damaged

Insufficient water pressure

Electrode damaged

Replace or adjust contacts*

Connect the wires

Replace

Check hydraulic installation  to pressure guarantee *

Replace

PROBLEM

Posible Cause

Solution

Magnetic sensor damaged

Switch ON/ OFF an the OFF position

connect the  switch at ON

Replace

Replace