background image

Manual | LORENTZ PP600H AC PowerPack  

v090315

PP600H AC PowerPack

 

Manual

AC/DC converter to power PS200/PS600/EP600 
pump systems from a generator or utility power

for PS1200/PS1800: see end of manual

Application

The Problem

Some solar pumps may not provide sufficient flow under all 
conditions, especially in unusually cloudy weather or when 
sufficient storage cannot be provided.

The Solution

LORENTZ AC PowerPack allows the pump to be powered 
by an AC generator or commercial utility power. The solar 
array remains connected. If the sun comes out again, less 
power is drawn from the AC source.

A common application is for a portable genset (gasoline 
generator) to run a well pump. When the generator is 
stopped (or runs out of fuel) the pump automatically re-
turns to solar power when the sunshine is sufficient. No 
manual switching is required.

The PowerPack will power the pump to its full capacity. 
With some systems, it will produce a greater flow rate than 
you will see with solar power.

Specifications

AC input: 115 V or 230 V (±15 %), selectable,  

• 

47 to 63 Hz

AC input current: 6.4 A (115 V) or 3.2 A (230 V)

• 

PV input voltage: Vmp: 55-130 V DC,  

• 

depending on pump controller max. voltages

Umax: 200 V DC 

• 

DC output: 75 V or 110 V, selectable, 700 W

• 

overload protection: internal fuse, 10 A

• 

enclosure: steel, gasket-sealed, outdoor-rated, hinged 

• 

front cover with key-lock

must be protected from direct mid-day sun

• 

IP42

• 

Dimensions

400mm × 300mm × 140mm 

• 

15.7 in × 11.8 in × 5.5 in

weight: 16 kg/35 lbs.

• 

Warranty 

Warranted to be free from defects in material and work-
man-ship for TWO YEARS from date of purchase.

WARNING Power Pack must be OFF 

while it is being wired to the solar 
pump controller, or controller damage 
may result. Never connect it while it is 
“hot”.

Wire Sizes

All wires must be #14 AWG (2.5 mm

2

) or larger.

AC Input Voltage Selection

Selection must be made by connecting a wire from terminal 
1 to either 2 or 3, as indicated on the terminal label. For 
115 V AC, connect 1-2. For 230 V AC, connect 1-3.

Grounding

Bond the metal enclosure to the ground connections of 
the AC power source and the solar power system. See your 
pump’s instruction manual.

AC Power Source

Install a 15 A circuit breaker at the power source or distri-
bution box.

INSTRUCTIONS

Installation

WARNING This device is to be in-

stalled, connected and serviced by 
qualified personnel only. Ensure all 
power sources are disconnected when 

making connections to this unit. Follow all appro-
priate electrical codes. There are no user-servicea-
ble parts inside.

Mounting

Mount the AC PowerPack close to the pump controller, in 
a vertical position. Cover the unit from direct rainfall. You 
will find four mounting brackets in a plastic bag inside the 
enclosure. 

WARNING PowerPack must be protect-

ed from solar heat, especially direct 
mid-day sun. Mount it in the shade. If 
there is no shady location, make a 

shade from sheet metal. Allow free air circulation 
around the cooling fins on the back of the enclo-
sure. For wall mounting, use spacers to stand it out, 
so the cooling fins do not touch the wall.

Отзывы: