V-Link
®
-200
User Manual
6.5
Terminal Block Connections
When inserting the sensor leads into the terminal block ensure the lead wire is being clamped under
the terminal screw and not the lead insulation. If the sensor wires are a very fine gauge, folding and
tinning them may be useful to provide more area for the terminal screw to make contact. Failure to
provide adequate connection may result in erroneous data.
Node Pin
Number
Signal
Node Pin
Number
Signal
1
SP+
16
SP+
2
S1+
17
S4+
3
S1-
18
S4-
4
GND
19
GND
5
S1 S
20
S4 S
6
SP+
21
Ain5
7
S2+
22
GND
8
S2-
23
Ain6
9
GND
24
GND
10
S2 S
25
Ain7
11
SP+
26
GND
12
S3+
27
Ain8
13
S3-
28
GND
14
GND
29
Vin
15
S3 S
30
GND
Table 3 -
Terminal Block Connections
41
Содержание V-Link-200