-200 is a 3-channel wireless sensor with a rugged, weatherproof 

enclosure. It includes onboard PGA, filtering, and a high-resolution ADC for 

precise measurement of a large range of sensor types including strain gauges, 

load cells, pressure transducers, and accelerometers. The SG-Link-200 

is ideal for both test and measurement and long term condition monitoring 

applications. 

Use this document to deploy the SG-Link-200 for data collection. This includes 

electrical wiring, mounting the device, and using SensorConnect software to 

configure the node, start sampling, and display data.

Figure 1.  SG-Link

®

-200

Indicator

Behavior

Node Status

Device status indicator

OFF

Node is OFF

Rapid green flashing on start-up

Node is booting up

1 (slow) green pulse per second

Node is idle and waiting for a 

command

1 green blink every 2 seconds

Node is sampling

Blue LED during sampling

Node is resynchronizing

Red LED

Built-in test error

Table 1.  Indicator Behaviors

Содержание SG-Link-200

Страница 1: ...easurement and long term condition monitoring applications Use this document to deploy the SG Link 200 for data collection This includes electrical wiring mounting the device and using SensorConnect software to configure the node start sampling and display data Figure 1 SG Link 200 Indicator Behavior Node Status Device status indicator OFF Node is OFF Rapid green flashing on start up Node is booti...

Страница 2: ...Pinout Descriptions 1 Pinout and Sensor Wiring Pin Name Description Pin Type Range Optional Cable 1 VIN External supply voltage Power input 4 0 to 36 V Red 2 GND Ground Power return GND Black 3 SP Sensor Excitation Voltage On continuously or duty cycle to the sensor to save power Analog Output 1 5V 2 5V 100 mA White 4 SP Sensor Excitation Voltage On continuously or duty cycle to the sensor to save...

Страница 3: ...ridge Figure 5 Three Wire Quarter Bridge Requires optional on board bridge completion Figures 2 through 5 illustrate Full Bridge Standard Half Bridge Two Wire Quarter Bridge and Three Wire Quarter Bridge wiring Figure 2 Full Bridge Standard Figure 3 Half Bridge ...

Страница 4: ...ows toggling between active and sleep mode The node will automatically enter into sleep mode after a user determined period of inactivity The node will not enter into sleep mode while active Figure 7 Node Operational Modes 2 Mounting Recommendations The SG Link 200 may be mounted using the holes sized for M8 fasteners Stainless steel compression limiters are rated for up to class 10 9 bolts Recomm...

Страница 5: ...Other Frequencies tile Figure 10 Node On Other Frequency 4 Install Software Install the SensorConnect software on the host computer before connecting hardware Access the free software download on the LORD Sensing website http www microstrain com software 5 Establish Gateway Communication Drivers for the USB gateways are included the SensorConnect software installation With the software installed t...

Страница 6: ... or may be on another frequency If Add Node Anyway is selected it associates that node with the channel entered but likely causes a communication error If the node was not in idle move the base station to the frequency of the node and issue a Set to Idle command Figure 14 Failure to Add Node Highlight the new node being added and select Move Node to Frequency Figure 11 Move Node C Manually Add Nod...

Страница 7: ...Node Configuration Menu The Hardware menu tab displays the current node settings 1 To change the default Input range settings use the dropdown menus found under Input Range This setting is used only when the Sensor Type is set to Uncompensated Resistance 2 To change the default Low Pass Filter settings use the dropdown menu found under Filter Cutoff 3 Select Apply Configuration to write to node me...

Страница 8: ...Sampled 2 Under the Sampling column select Sample Rate from the drop down menu Select Continuously to sample indefinitely Figure 18 Sampling Setting 3 Select Apply and Start Network A message indicates the Network Started and includes a shortcut link to the Data Tab Figure 19 Network Started with shortcut to Data Tab 4 Navigate to the Data tab and view the Empty Dashboard 1 Click the Add Widget bu...

Страница 9: ...ications including antenna changes not expressly approved by LORD Corporation could void the user s authority to operate the equipment Cet appareil est conforme à la Partie 15 des Règles de la FCC des États Unis et aux RSSS exempts de licence d Industrie Canada Le fonctionnement est soumis aux deux conditions suivantes 1 Cet appareil ne doit pas causer d interférences et 2 Cet appareil doit accept...

Страница 10: ...y Lithium batteries contain toxic chemicals that are harmful to humans and the environment Disposal is subject to federal and local laws Do not discard the battery or the node in the trash Follow proper battery disposal protocol or contact LORD Sensing Technical Support for information on extracting the battery or returning the product for proper recycling and disposal 11 Power Supply Apply only t...

Отзывы: