3DM
®
-GX5-35
DCP Manual
float – Up compensation time constant (sec)
float – North compensation time constant (sec)
Examples
MIP Packet Header
Command/Reply Fields
Checksum
Sync1
Sync2
Desc.
Set
Payload
Length
Field
Length
Field
Desc.
Field Data
MSB
LSB
Command
0x75
0x65
0x0C
0x0D
0x0D
0x51
Fctn Selector
(Write):
0x01
Up Compensation
Enable:
0x01
North
Compensation
Enable:
0x01
Up Compensation
Time Constant:
5.0
(sec)
North
Compensation Time
Constant:
5.0
(sec)
0xXX
0xXX
Reply Field :
ACK/NACK
0x75
0x65
0x0C
0x04
0x04
0xF1
Echo cmd: 0x51
Error code: 0x00
0x
0x
Copy-Paste version of the command: “7565 0C09 0951 0104 0100 0000 00"
4.2.22
Device Status (0x0C, 0x64)
Description
Get the device-specific status for the 3DM-GX5-35.
Reply has two fields: “ACK/NACK” and “Device Status Field”. The device status field
may be one of two selectable formats – basic and diagnostic.
The reply data for this command is device specific. The reply is specified by two
parameters in the command. The first parameter is the model number (which for the
3DM-GX5-35 is always = 6252 (0x186C). That is followed by a status selector byte
which determines the type of data structure returned. In the case of the 3DM-GX5-35,
there are two selector values – one to return a basic status structure and a second to
return an extensive diagnostics status structure. A list of available values for the
selector values and specific fields in the data structure are as follows:
Possible Status Selector Values:
0x01 – Basic Status Structure
0x02 – Diagnostic Status Structure
Notes
The reply field for this command is tightly tied to the model number. Make sure
you check the model number in the reply and match it to the correct structure for the data
field for the specific device model number. This reply data descriptor 0x0C,0X90 is an
64