The contents of the diagnostic packet may be viewed in the Data tab within SensorConnect.
Description
Data Values
Data Type
Unit
Current State
0 = Idle
1 = Deep sleep
2 = Active run
3 = Inactive run
uint8
--
Run Time
Idle
uint32
seconds
Deep sleep
uint32
seconds
Active run
uint32
seconds
Inactive run
uint32
seconds
Reset Counter
--
uint16
counts
Built in Test
Result
0 = no errors
uint32
--
Internal
Temperature
Valid range: -40 to 125° C
sint8
Celsius
Low Battery
Indicator
0 = good
1 = low
2 = critical (sensor will
stop sampling)
uint8
--
External Power
0 = not connected
1 = external power
connected
uint8
--
Sample Info
Sweep index
uint32
counts
Bad sweep count
uint32
counts
Transmission Info
Total transmissions
uint32
counts
Total retransmissions
uint32
counts
Total dropped packets
uint32
counts
Synchronization
Info
Synchronization attempts
uint32
counts
Synchronization failures
uint32
counts
Seconds since last
synchronization
uint32
counts
Event Trigger
Index
--
uint16
counts
Table 3 -
Diagnostic Packet
Содержание Sensing SG-Link-200
Страница 1: ...LORD Sensing USER MANUAL SG Link 200 Wireless Analog Input Node...
Страница 26: ...SG Link 200 User Manual 26 Figure 19 Event Triggered Sampling...
Страница 31: ...SG Link 200 User Manual 31 Figure 24 MathEngine View Figure 25 FFT Graph in SensorCloud...
Страница 38: ...SG Link 200 User Manual 38 8 Troubleshooting 8 1 Troubleshooting Guide...
Страница 44: ...SG Link 200 User Manual 44 b Operating Specifications...