Chapter 5 Terminal Operation IP6704A TDMoEthernet
Loop Telecommunication International, Inc.
63
K
> Clock Source Setup
The screen of Clock Source Setup will show as below.
5.5.1.
Clock Source Setup
The full menu path for Clock Source Setup is as follows:
O
> Logon
K
> Clock Source Setup
A
> Clock Source Setup
Input the port number (A~D): A
The screen of Clock Source Setup will show as below.
E1 P ort A == = C loc k S our ce Setu p = == 13: 09: 06 01 / 18/ 201 6
ARRO W K EYS : C URS OR MOV E, TAB : R OLL OP TIO NS
Mast er_ Clk So urc e : IN TER NAL
Seco nd_ Clk So urc e : IN TER NAL
Curr ent Cl ock : MA STE R_C LK
Clk_ Rec ove r_M ode : AU TOM ATI C
Cloc k S tat us : NO RMA L
Por t B ID Ena ble St atu s
ACR1 : A 0 OFF id le
ACR2 : A 0 OFF id le
ACR3 : A 0 OFF id le
ACR4 : A 0 OFF id le
<< P res s E SC key to re tur n t o p rev iou s m enu or sav e t he set up> >
Table 5-26 Clock Source Setup
Field
Setting Options
Default Setting
Master_Clk Source
A(LINE), B(LINE), C(LINE), D(LINE),
ACR1, ACR2, ACR3, ACR4,
INTERNAL, SyncE
INTERNAL
Second_Clk Source
A(LINE), B(LINE), C(LINE), D(LINE),
ACR1, ACR2, ACR3, ACR4,
INTERNAL, SyncE
INTERNAL
Current Clock
INTERNAL, MASTER_CLK,
SECOND_CLK
MASTER_CLK
Clk_Recover_Mode
AUTOMATIC, MANUAL
AUTOMATIC
IP67 04A T1 = == Clo ck So urc e Setu p = == 13: 09: 06 01 /18 /20 16
A -> Cl ock So urc e S etu p
B -> Sy ncE Cl ock Se tup
<< E SC key to re tur n t o p rev iou s m enu , S PAC E ba r t o r efr esh >>