4/29/2020
Loongson 3A3000 / 3B3000 Processor User Manual
13
11
Figure 1-1 Loongson No. 3 system structure
The structure of Loongson No. 3 node is shown in Figure 1-2 below. Each node has two levels of AXI crossbars connected to the processor and shared
Page 16
Godson 3A3000 / 3B3000 Processor User Manual • Volume 1
12
Cache, memory controller and IO controller. Among them, the first level AXI crossbar switch (called X1 Switch, referred to as X1)
Connect the processor and shared cache. The second level crossbar switch (called X2 Switch, referred to as X2 for short) is connected to share Cache and
Memory controller.
Figure 1-2 Loongson No. 3 node structure
In each node, up to 8 * 8 X1 crossbars are connected to four GS464 processor cores through four Master ports
(P0, P1, P2, P3 in the figure), connected to four interleave shared caches with four slave ports through four slave ports
Block (S0, S1, S2, S3 in the figure), connected to the four directions of east, south, west and north through four pairs of Master / Slave
Other nodes or IO nodes (EM / ES, SM / SS, WM / WS, NM / NS in the figure).
The X2 crossbar is connected to four shared caches through four Master ports, and one is connected to at least one Slave port
Memory controller, at least one Slave port connected to a crossbar configuration module (Xconf) is used to configure this node
The X1 and X2 address windows, etc. You can also connect more memory controllers and IO ports as needed.
1.2 Introduction to Godson 3A3000 / 3B3000
Loongson 3A3000 / 3B3000 is a process upgrade version of Loongson 3A2000 / 3B2000 quad-core processor.
Compared with the core 3A1000, PLL_AVDD is changed from 2.5V to 1.8V, which is more used than the Loongson 3A2000 / 3B2000
PLL_AVDD. Loongson 3A3000 / 3B3000 is a single-node 4-core processor, manufactured using 28nm process,
The main frequency is 1.2GHz-1.5GHz, and the main technical characteristics are as follows:
EM
X1 Switch
S0
P0
P1
P2
P3
S1
S2
S3
WM
WS
NM
SM
NS
ES
SS
m0
m1
m2
m3
m4
m5
m6
m7
s0
s1
s2
s3
s4
s5
s6
s7
MA0
MA1
MA2
MA3
X2 Switch
MC
Xconf