Страница 1: ...1 Operating manual a Look Solutions product cobra 3 1...

Страница 2: ...anual version 2 2018 1 Cobra 3 1 fog generator incl Duct Adaptor Protection against contact 1 Tank lid with Quick Connector 1 mains cable 2 m with Powercon True plug 1 Operating manual Please check wh...

Страница 3: ...12 5 4 2 Manual operation 13 5 4 3 Operating via analogue 14 5 4 4 Operating via DMX 15 5 4 5 Operating via Ethernet 17 5 4 5 1 Artnet 17 5 4 5 2 sACN 18 5 4 5 3 IP Configuration 19 5 4 6 Using the in...

Страница 4: ...intuitive Beside the analogue and DMX 512 control the machine can also be operated via Ethernet Artnet and sACN The machine is equipped with the following RDM features Status Ready Re heating Error me...

Страница 5: ...g set The visibility has to be more than 2 m in rooms where people walk around Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water Consult a doctor...

Страница 6: ...6 3 Description of the parts 11 13 12 14 Tank lid 1 3 2 3 1 Fog nozzle 2 Duct Adaptor Protection against contact 3 Air vents Front view Coupling Collar Tank lid Check valve 11 12 13 14...

Страница 7: ...7 Rear view 3 Description of the parts 4 Touchscreen Control Panel 5 Ethernet Connector RJ45 Ethercon 6 DMX512 in out 5pin XLR 7 Analogue in 3pin XLR 8 Power in out for Powercon True plug 7 8 6 5 4...

Страница 8: ...ilable Quick Fog thick quick disappearing fog fluid Regular Fog thick long lasting fog fluid Slow Fog thick extremely long lasting fog fluid If fluids have been used other than Look fog fluids we can...

Страница 9: ...ne is heated up the START button changes from red to green Fig 1 Machine not ready Fig 2 Machine ready 5 3 Switching the device off At manual operation disconnect the mains plug or switch the machine...

Страница 10: ...n with all other controls 2 Operation via analogue 3 Operation via DMX 4 Operation via Ethernet overwrites everything else The chosen active function will be highlighted at the Touchscreen in cyan In...

Страница 11: ...perature or how far the heating process has progressed The display increases from 0 to 100 which performance curve characteristic MODE has been selected By pressing MODE the display changes into the M...

Страница 12: ...d regulates down to continuous output The pump will not be switched off and the fog output won t stop 4 CONTINUOUS In this Mode the pump can only be set to 30 as maximum to ensure a steady continuous...

Страница 13: ...selected performance curve characteristic also effects the amount of the fog output Thus although 100 has been adjusted the output will eventually be lower See chapter 5 4 1 Fig 5 Manual Mode The foll...

Страница 14: ...e DIRECT or LATCHED Also the colour of the button cyan shows that the analogue mode is now active To adjust the analogue Mode press ANALOG on the main screen Fig 1 Line 1 or choose SETTINGS and on the...

Страница 15: ...Remote the fogging process can be started by pressing the on off Button on the XLR Remote When using the Radio Remote the start button on the transmitter has to be pressed and held during the fogging...

Страница 16: ...fog output If Personality VALUE MODE has been choosen the machine can be controlled via two following DMX channels The first channel regulates the pump the second one selects the pump mode See chapter...

Страница 17: ...MODIFY Fig 12 The screen shown on the right Fig 13 appears Corresponding to the standards for DMX and ARTNET a Universe consists of 512 DMX channels A Subnet contains 16 Universes and a Net 16 Subnets...

Страница 18: ...f 512 DMX channels In sACN there are Universes between 1 and 63999 Press CE Fig 15 and type in the value for the selected Universe sACN UNIVERSE SAVE saves the value BACK switches back to the previous...

Страница 19: ...and a subnet mask from a DHCP Server or Router in your network If you select STATIC you can type in the IP address and the subnet mask in the following screen Fig 17 Ask your network administrator if...

Страница 20: ...inutes can be adjusted The Timer can be started manually as well as via Remote To select the starting Mode press TRIGGER Depending on the Mode that has been choosen the screen shows MAN or REM Further...

Страница 21: ...you can adapt the differences Save the value with PUMP ADJ SAVE Press BACK to get to the previous screen without saving the value Pump Adjustment Adjusts the time until the Screensaver appears Press S...

Страница 22: ...witch directly to the Standby Mode Standby You can adjust the brightness of the back ground lighting Press SETTINGS at the main screen on the fol lowing Settings 1 screen NEXT and on the Settings 2 sc...

Страница 23: ...needed More info on request Machine Information Here you can switch back to the default settings Press SETTINGS at the main screen in the fol lowing Settings 1 and Settings 2 screen NEXT and in the S...

Страница 24: ...his reduces the chances of the machine clogging up If you install the Cobra 3 1 make 100 sure that a permanent fog free air supply for the unit is guaranteed Cooling air with too high fog concentratio...

Страница 25: ...gged Check that pump setting on the machine is 1 The fog machine fogs uncontrollably Check mains supply Check unit for moisture moisture inside the machine especially on the PCB can cause fogging The...

Страница 26: ...1 Output projection max 25 m Fogging time at 100 output Extended Mode approx 55 sec Impulse Mode approx 22 sec at 30 output continuous output Control Manual 0 10 V analogue DMX 512 Ethernet Artnet sAC...

Страница 27: ...d persons and or if spare parts are used which are not approved by us The right of guarantee service is also lost if fluids other than original Look fog fluids have been used or if units are sent to u...

Страница 28: ...28 a Look Solutions product...