background image

LTCU

 

SERIES

 

USER

 

MANUAL

 

 

Thank

 

you

 

for

 

selecting

 

this

 

UPS.

 

It

 

provides

 

you

 

with

 

better

 

protection

 

for

 

connected

 

equipments.

 

 

Please

 

read

 

this

 

manual!

 

 

This

 

manual

 

provides

 

safety,

 

installation

 

and

 

operation

 

instructions

 

which

 

will

 

guide

 

you

 

to

 

the

 

best

 

performance

 

of

 

your

 

equipment.

 

 

Please

 

save

 

this

 

manual!

 

 

It

 

includes

 

important

 

instructions

 

for

 

the

 

safe

 

usage

 

of

 

the

 

equipment

 

and

 

to

 

obtain

 

manufacturer’s

 

support

 

in

 

case

 

of

 

need.

 

 

Please

 

keep

 

or

 

recycle

 

the

 

packaging

 

materials!

 

 

Packaging

 

materials

 

used

 

in

 

our

 

products

 

are

 

designed

 

to

 

provide

 

protection

 

from

 

transportation.

 

These

 

materials

 

are

 

necessary

 

in

 

case

 

that

 

the

 

equipment

 

needs

 

to

 

be

 

shipped

 

back

 

for

 

service.

 

Damage

 

that

 

may

 

occur

 

during

 

the

 

shipment

 

is

 

not

 

covered

 

by

 

the

 

product’s

 

warranty.

 

 

1.

 

INTRODUCTION

                                   

 

1

1

 

System

 

Description

 

 

The

 

product

 

is

 

line

 

interactive

 

UPS

 

with

 

LCD

 

display,

 

newest

 

technology

 

and

 

powerful

 

function.

 

The

 

line

 

interactive

 

UPS

 

is

 

designed

 

with

 

2

 

steps

 

boost

 

and

 

1

 

step

 

buck

 

AVR

 

to

 

stabilize

 

input

 

voltage.

 

Input

 

voltage

 

range

 

is

   

30%,

 

+25%,

 

but

 

output

 

regulation

 

is

 

+/

‐ 

10%.

 

The

 

line

 

interactive

 

UPS

 

provides

 

you

 

with

 

the

 

ability

 

of

 

perfect

 

protection

 

for

 

your

 

critical

 

devices.

 

 

1

2

 

Features

 

 

z

 

Line

 

interactive

 

design.

 

z

 

Microprocessor

 

control

 

guarantees

 

high

 

reliability.

 

z

 

Frequency

 

50Hz/60Hz

 

auto

 

sensing.

 

z

 

Equipped

 

with

 

2

 

steps

 

boost

 

and

 

1

 

step

 

buck

 

AVR

 

to

 

stabilize

 

Utility

 

voltage.

 

z

 

Built

in

 

DC

 

start

 

function

 

enable

 

UPS

 

to

 

be

 

started

 

up

 

without

 

AC

 

power

 

supplied.

 

z

 

UPS

 

green

 

mode

 

(Energy

 

saving

 

function).

 

z

 

Off

 

mode

 

charging.

 

z

 

Modem

 

/

 

phone

 

line

 

surge

 

protection.

 

z

 

Over

 

/

 

low

 

voltage,

 

short

 

circuit,

 

lighting,

 

surge

 

(option)

 

protection.

 

 

2.

 

CAUTION

                                               

 

z

 

The

 

UPS

 

contains

 

voltage

 

that

 

is

 

potentially

 

hazardous.

 

Qualified

 

or

 

certified

 

technician

 

should

 

proceed

 

all

 

repairs

 

and

 

maintenance.

 

z

 

The

 

UPS

 

has

 

its

 

own

 

internal

 

energy

 

source

 

(battery).

 

The

 

output

 

receptacles

 

may

 

be

 

active

 

even

 

when

 

the

 

UPS

 

is

 

not

 

connected

 

to

 

the

 

Utility.

 

z

 

The

 

UPS

 

is

 

suitable

 

for

 

computers

 

and

 

electronic

 

equipment

 

with

 

substantial

 

rectifier

 

or

 

capacitive

 

loads,

 

not

 

suitable

 

for

 

electronic

 

equipment

 

with

 

significant

 

inductive

 

loads

 

such

 

as

 

motors

 

and

 

fluorescent

 

lamps.

 

z

 

Be

 

sure

 

to

 

operate

 

within

 

the

 

power

 

rating

 

of

 

the

 

UPS.

 

Below

 

1/2

 

or

 

1/3

 

of

 

the

 

rated

 

power

 

is

 

recommended

 

for

 

longer

 

backup

 

time

 

and

 

longer

 

battery

 

life.

 

z

 

Do

 

not

 

place

 

the

 

UPS

 

near

 

excessive

 

humidity,

 

under

 

sunshine

 

or

 

close

 

to

 

heat

 

emitting

 

sources.

 

z

 

If

 

the

 

UPS

 

is

 

out

 

of

 

order,

 

detach

 

the

 

power

 

cord

 

and

 

consult

 

your

 

dealer

 

right

 

away.

 

Do

 

not

remove

 

cover,

 

there

 

is

 

no

 

serviceable

 

part

 

inside.

 

z

 

The

 

unit

 

should

 

be

 

supplied

 

by

 

a

 

grounded

 

source.

 

Do

 

not

 

operate

 

the

 

unit

 

without

 

a

 

ground

 

source.

 

z

 

The

 

socket

 

should

 

be

 

installed

 

near

 

the

 

equipment

 

and

 

be

 

easily

 

accessible.

 

z

 

Do

 

not

 

plug

 

the

 

UPS

 

power

 

cord

 

into

 

itself.

 

That

 

will

 

result

 

in

 

a

 

safety

 

hazard.

 

z

 

A

 

qualified

 

technician

 

or

 

electrician

 

in

 

accordance

 

with

 

local

 

electrical

 

code

 

should

 

perform

 

installation.

 

 

3.

 

INSTALLATION

                                 

 

The

 

UPS

 

must

 

be

 

installed

 

in

 

a

 

protected

 

environment

 

away

 

from

 

heat

 

emitting

 

appliances

 

such

 

as

 

a

 

radiator

 

or

 

heater.

 

Do

 

not

 

install

 

this

 

product

 

where

 

excessive

 

moisture

 

is

 

present.

 

 

 

 

Caution:

 

Never

 

connect

 

a

 

laser

 

printer

 

or

 

plotter

 

to

 

the

 

UPS.

 

A

 

laser

 

printer

 

or

 

plotter

 

periodically

 

draws

 

significantly

 

more

 

power

 

that

 

its

 

idle

 

status,

 

and

 

may

 

overload

 

the

 

UPS.

 

 

4.

 

OVERVIEW

                                       

 

 

 

5.

 

OPERATION

                                   

 

 

z

 

When

 

the

 

UPS

 

is

 

connected

 

to

 

the

 

Utility,

 

but

 

UPS

 

is

 

not

 

powered

 

on,

 

UPS

 

will

 

charge

 

battery

 

automatically

 

and

 

LCD

 

display

 

will

 

show

 

“UPS

 

OFF”.

 

Please

 

press

 

main

 

switch

 

on

 

front

 

panel

 

for

 

1

 

second

 

to

 

turn

 

on

 

UPS.

 

 

z

 

To

 

turn

 

off

 

UPS

 

when

 

UPS

 

is

 

under

 

AC

 

mode,

 

please

 

press

 

main

 

switch

 

on

 

front

 

panel

 

for

 

4

 

seconds.

 

To

 

turn

 

off

 

UPS

 

when

 

UPS

 

is

 

under

 

battery

 

mode,

 

press

 

main

 

switch

 

and

 

then

 

UPS

 

will

 

shut

 

down

 

completely

 

in

 

10

 

seconds.

 

 
 