Carbon Monoxide detector operating manual

Product Overview

This product is the high stable Carbon monoxide detector
(below abbr as the detector), it use for detecting the 
leakage of the carbon monoxide. It is made of the most 
advanced electrochemistry carbon monoxide sensor, it 
with high stability, sensitivity drift small such character. 
This product use the backlit digital LCD to display the 
alarm level. The detector can operates with the voltage 
between AC110-230V, after installing with the standby 
battery function. When the detector detects the carbon 
monoxide leaks and the thickness reach the default 
alarm level, the detector red LED ash and sounds. This 
product suits for the all the places that might produce the 
carbon monoxide.

Funtion Feature

LCD display the carbon monoxide alarm level
Use the microprocessor control
High reliability sensor design
Breakdown automatic check indicate and display
Alarm auto reset function
Use SMT crafting,high stability
With after-use battery standby function
Wireless output(315M/433M)
Relay output(3A/AC220V or 3A/DC30V) 

Technical parameter

Operating voltage

AC110-230V,50~60Hz, 9V Ni-Mh rechargeable battery
(optional)

Never restart the source of a CO problem until it has been 
xed. NEVER IGNORE THE ALARM!
The CO sensor sensitivity and setting is:
30ppm  within 120 minutes
50ppm  within 60-90 minutes
100ppm  within 10-40 minutes
300ppm  within 3 minutes

Alarm current

Static current

Warm up time

about 60s

Alarm sensitivity

electrochemistry sensor

Sensor

LCD display

display the alarm sensitivity/display the detected gas/ 
display the power supply way/begin to display when the 
carbon monoxide is more than 25ppm.

AC: the green LED lighting
Alarm: the red LED ashing
Sensor breakdown: the yellow LED lighting

Indicator info

Enviroment temperature

SPL : ≥85db

 ≥85db

-10ºC~+50ºC

Environment humility

10%-90% (No condensation phenomenon)

Size

Mounting

138-90-40mm

wall mounting or 

Wiring installing instruction

All the wiring installing need to follow the national or the 
local law and standard. The thickness of the wire stylet 
need to be properly. the improperly connection may lead 
the detector does not alarm when the carbon monoxide 
leak.

Product Installing

1. This product suits for plug type mounting and wall 
    mounting, choose the properly place, generally on 
    the ceiling above where have the carbon monoxide, 
    the distance is about 2m.

2. Static the installing support x on the ceiling, and 
    insert the detector on the installing support. Or choose 
    the place where there is the plug board, and plug the 
    detector on the plug board directly.
3. Home usage detector need to avoid installing near the 
    gas stove, to avoid the detector be heated by the re 
    from the stove; avoid install in the place where has 
    strong smoke, it might lead false alarm or effect the 
    detector sensor’s sensitivity; avoid install near the 
    ventilating fans, windows and bathroom these high air 
    ow areas.
4. The wiring connects need to follow the installing 
    diagram, all the wiring need to follows the national and 
    local laws, standards. The wiring thickness should be 
    properly, the wiring connects the detector and the 
    other assisted device should be marked colors, to 
    avoid connect wrongly. The improperly wiring 
    connection might lead the detector don’t alarm 
    correctly when it detect the leakage of the carbon 
    monoxide.

Operating instruction

1. Supply the detector with power. The detector enter 
    the auto-check status, the green LED, red LED, yellow
    LED indicator ash 1 time at the same time, the buzzer 
    sounds ‘di’ 1 time. Then the detector enter the warm-up 
    status, LCD symbol display in turn, warm up need 
    about 60s, the LCD back light close, LCD display the 
    power supply and check the gas’ chemical symbol, it 
    means the detector enter monitoring status. Warm-up 
    period prohibit use the gas to test. When the outside 
    AC power stop to supply, the detector will automatic 
    change the standby battery to supply. When the battery 
    volume is too low, LCD will display the low battery 
    volume mark, the green indicator will ash 1 time every 
    12s,and with the buzzer sounds 1 ‘di’.

Power

Alarm

Fault

power indicator

alarm indicator

breakdown indicator

testing buttor

Relay output wiring

Power wiring

Alarm signal wiring

 

connection diagram

detector

detector

gas stove