GENERAL DESCRIPTION AND TECHNICAL DATA
- 2
2.3 Summary diagram of the
air-conditioning system for model :
350 C
CONVENTIONAL COOLING CYCLE
The diagram in Tab 6 shows the flow chart of the conditioning process:
HP)
High pressure - Compression (min 10 - max 27 bars _coolant R 134 a);
LP)
Low pressure - Intake (min 1 - max 5 – bars_coolant R 134 a);
N.B.:
Optimal values for a correct functioning of the system
are: suc 1.5 ÷ 2.0 (bar) - dics 13÷17 (bar)
LEGEND:
1 COMPRESSOR AC;
2 AC CONDENSER;
3 DEWATERING FILTER;
4 EXPANSION VALVE;
5 EVAPORATOR AC;
GAS R134a LOW PRESSURE (LP)