Installation
2.
Remove the screw from the top of the metal cover plate
and lower it down carefully
3.
The Mains Filter is mounted inside the panel housing mounted on the right hand side.
4.
Push the mains cable up through one of the available cable glands. Then Split the cable
inside the box and cut the wires to suitable lengths. An armoured/braided cable is
recommended when cable conduit is not used. A suitable earth conductor is also to be fitted.
5.
Crimp connectors onto the wires and connect to the Mains Filter as specified in the table
below.
6.
Check that all connections are secure then refit the metal cover plate and front cover.
Ensure that the front panel cover fixing bolts have been tightened to 4Nm torque to maintain
the integrity of the IP69K rating for the head; preventing ingress of water or condensation.
European
Colour
North America
Colour
Terminal
LIVE
Brown or Black
HOT
Black
L
NEUTRAL
Blue
NEUTRAL
White
N
EARTH
Green/Yellow
GROUND
Green
E
SCREEN
-
SCREEN
-
E