Logs and Reports
■
Problem:
Bin full - the reject bin full sensor has been blocked for longer than 5 seconds and
the transport system has stopped. The bin will need to be emptied before the transport can be
restarted.
o
Action:
If the bin is full:
1. Remove, identify and segregate the product. Once the sensor is unblocked the fault
will automatically clear.
If the bin is not full:
1. Check the Bin full sensor is working correctly.
■
Problem:
Link corrupted - data corruption has occurred between the detector and LomaLink
PC or other controlling device. The operation of the detector is unaffected.
o
Action:
1. Check cabling and link connectors from remote device.
2. Check LomaLink PC or other controlling device for reported errors.
■
Problem:
Link failure - a break in communication between the detector and LomaLink
PC/other controlling device. The operation of the detector is unaffected.
o
Action:
1. Check cabling and link connectors from remote device.
2. Check connections between the detector and LomaLink PC or other controlling device
for loose or broken wiring/connectors.
■
Problem:
PV test timeout - an automated prompt for the PV test has either not been actioned
or completed within the window time set. The transport system may have stopped.
o
Action:
Clear system fault (restart the transport if stopped) and perform a
■
Problem:
PEC obstructed - the product registration photo-eye has remained blocked for
greater than 6 consecutive pack lengths. This fault is only generated if the PEC fault is
enabled.
o
Actions:
1. Check the PEC for blockage.
2. Check the PEC is working correctly.
3. Check pack flow length entry is adequate in the
Menus > Set Up > Product
menu,
ensuring an allowance is made for pack skew.
4. Ensure the correct belt speed is entered in the
Menus > Service > Configuration >
System
menu..
■
Problem:
Wrong flash c/sum - the software has compared the flash checksum currently
stored in its memory with the checksum for recently installed software. This occurs if a
software update has been done and a hardware cold start was not performed after
installation.
o
Action:
1. Perform an update to the Flash Checksum in the
Menus > Machine Details
menu.
112
Содержание IQ3
Страница 2: ......
Страница 10: ......
Страница 26: ......
Страница 43: ...Installation 33 ...
Страница 60: ...Installation THIS PAGE IS INTENTIONALLY LEFT BLANK 50 ...
Страница 70: ...About the Metal Detector Range THIS PAGE IS INTENTIONALLY LEFT BLANK 60 ...
Страница 74: ...Getting Started IQ3 Dual Line Display Menu Map 64 ...
Страница 116: ...Operating Instructions THIS PAGE IS INTENTIONALLY LEFT BLANK 106 ...
Страница 140: ...Maintenance THIS PAGE IS INTENTIONALLY LEFT BLANK 130 ...