Configuration and Set up Information
Module 7026
5-28
Serial link menu configuration
The serial link menu protocol for link 1 is configured as follows:
Link 1 may be set to one of the following options. Press
[
"
""
"
] to select the usage list
then again and use the [
!
] to select one of the uses below.
USAGE
- “NOT USED” is the default setting
LOMALINK
- For use with LomaLink control protocol.
or
- For use with LomaView management systems.
REPORTS
- For use with LomaNet or a single printer.
Press
[
"
""
"
] to accept.
When LomaLink or Reports is selected further menu entries within the link allow the
protocol to be set.
Press the
[
!
] key to step down the menu below.
* Baud rate
-
150, 300, 600, 1200, 2400, 4800, 9600
* Data bits
-
7 or 8
* Stop bits
-
1, 1.5 OR 2
* Parity
-
ODD, EVEN or NO
* Flow Ctrl
-
NONE, CTS-RTS or XON-XOFF
Pressing the
[
"
""
"
] key in any menu position changes the “
*
” to a “>“, use the “
[
$
]
[
!
]”
keys to select entry required then press
[
"
""
"
] key again to accept.
Pressing the [
C
] Key will exit the menu without making any changes.
NOTES
Please refer to the Displaying and printing reports in your user manual if using the
report option, or appropriate LomaView, LomaNet or LomaLink information.
Содержание IQ2
Страница 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Страница 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Страница 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Страница 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...