Fault and Error Diagnosis
Module 6022
4-3
Run Errors
Are classified as non-fatal but requires an operator's attention. When an error is
generated the attention relay operates and subsequently any remote device connected
to it. In addition the Run Error LED
!
!
!
!
on the User Interface illuminates. If your
detector is fitted with the Reports/Logs package the errors can be accessed in the Run
Error menu "View errors". All errors are described as either passive (PSV), active
(ACT) or as an event (EVT) the date & time accompany errors.
Message
Cause
Solution
LomaLink
Error No.
PV test
prompt
A programmed PVS test
prompt has occurred.
1. Complete a PV Test.
22
Pec blocked
PEC has remained blocked for
5 consecutive pack lengths.
Product registration photoeye
only.
1. Check the PEC for
blockage.
2. Check PEC is
working.
3. Check pack flow
length entry is adequate,
ensuring an allowance is
made for pack skewing.
4. Ensure correct belt
speed is entered.
23
Neg delay
exten
Reject dwell time setting
problem. Variable speed
systems only.
1. Check reject delay
and dwell time settings.
24
Speed too fast
Belt speed is greater than the
upper limit for existing filter
resistors, coil gap and belt
speed. Variable speed systems
only.
1. Decrease belt speed.
2. Change filter resistors
to lower value. Refer to
on page 14
in
the “Configuration &
Setup” section of this
manual
25
Speed too
slow
Belt speed is less than the
lower limit for existing filter
resistors, coil gap and belt
speed. Variable speed
systems.
1. Increase belt speed.
2. Change filter resistors
to higher value. Refer to
on page 14
in
the “Configuration &
Setup” section of this
manual
26
Reject too
close
The reject system is still
counting out the dwell for a
reject when the next pack to be
rejected comes along
1. Reduced the reject
dwell time.
2. Improve the pack
pitch.
3. If the reject is a
retracting band or
lift/drop flap, change the
reject mode to pulse
extension.
27
Reject
disabled
The reject relay has been
disabled.
1. Enable the reject
relay using the Reject
enable command.
29
Note:
PEC = Photo Electric Cell or Photoeye.
PVS = Performance Validation System.
Содержание IQ2
Страница 92: ...Maintenance Module 8023 6 1 Frequency links Tx Inductors Balance inductors ...
Страница 101: ...Wiring Diagrams Module 10088 8 2 Figure 1 Optional External Sensor Connection Ladder Diagram ...
Страница 102: ...Spare Parts Module 11050 9 1 SPARE PARTS CONTENTS Spare Parts Lists 2 ...
Страница 104: ...Service Return Module 12005 8 1 SERVICE RETURNS FORMS CONTENTS Instructions 2 Form 3 ...