LogTag Recorders UTREL30-16-WIFI Скачать руководство пользователя страница 1

UTREL30-WiFi

Wireless Low-

Temperature Data Logger

 
 

Product User Guide

LogTag Recorders

 

Document Release Version: 1.0

Published 21. December 2020

Copyright © LogTag Recorders, 2004-2020

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание UTREL30-16-WIFI

Страница 1: ...rature Data Logger Product User Guide LogTag Recorders Document Release Version 1 0 Published 21 December 2020 Copyright LogTag Recorders 2004 2020 www GlobalTestSupply com Find Quality Products Onlin...

Страница 2: ...battery and may cause injuries Empty batteries should be recycled or disposed of according to your local regulations Liability LogTag Recorders standard warranty terms apply A copy can be requested b...

Страница 3: ...e has been tested and complies with the FCC IC RSS 210 CE and SRRC rules and regulations for intentional transmitters Any limits in these regulations typically are designed to provide reasonable prote...

Страница 4: ...he product This text describes certain aspects of the product where incorrect use of a feature may lead to inadvertent loss of data This text contains important information for the correct operation o...

Страница 5: ...igger summary of up to the last 30 days today and 29 days previous and l the wireless and cloud connection states At set intervals the UTREL30 WiFi uploads the data to your LogTag Online cloud account...

Страница 6: ...t with attached protective cap l Gold plated high quality temperature sensor socket l Robust polycarbonate case IP51 l 2 user replaceable AAA backup batteries accessible via a compartment at the rear...

Страница 7: ...ill accept any external probe from the ST10 product range Communication The UTREL30 WiFi offers two means of downloading data 1 Use the built in Micro USB socket to transfer data directly to a PC 2 Us...

Страница 8: ...r Guide 11 and also includes a day summary page showing an overview of the statistics collected A CSV file of the data list is also available www GlobalTestSupply com Find Quality Products Online at s...

Страница 9: ...of the ST10 series l A PC running Windows 7 SP1 or later and LogTag Analyzer 3 installed or a stand alone version of the LogTag Online Connection Wizard l A PC with PDF reader software installed for v...

Страница 10: ...Need UTREL30 WiFi User Guide 13 l A silica sand temperature buffer which simulates environmental behavior of a vaccine vial www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSu...

Страница 11: ...the UTREL30 WiFi to your wireless network using the LogTag Online Connection Wizard 5 Complete the device setup in LogTag Online including associating the UTREL30 WiFi with a location You can find mor...

Страница 12: ...om the rear compartment lid 2 Remove the lid exposing the battery compartment 3 Insert the AAA batteries in the correct orientation as shown The polarity is marked inside the battery compartment 4 Rep...

Страница 13: ...ble Also your reseller may have already configured the device to be connected to your wireless network You can check if your logger is already configured or not by briefly pressing the REVIEW MARK but...

Страница 14: ...ware which can also be used for downloading and analyzing data LogTag Analyzer includes the LogTag Online Connection Wizard which will allow you to set wireless and network settings and register the U...

Страница 15: ...nline 3 Attach the UTREL30 WiFi to a location During the attachment process select one of the pre defined Logger Configuration Profiles Each profile contains l the log interval l alarm settings for al...

Страница 16: ...settings such as User ID start method pre start recording logging interval and duration start delay and password Adjust the settings as required For detailed information about each parameter please re...

Страница 17: ...readings is a good way to avoid data loss if you forget to start the unit as you can still access the data using LogTag Analyzer Start delay If you configure the UTREL30 WiFi to start after a delay pe...

Страница 18: ...an upper alarm If an alarm trigger condition requires readings to go below a lower threshold it is called a lower alarm All alarm trigger conditions are configured in the Alarm Settings tab during con...

Страница 19: ...ext this marker will move to and so on Alarm Re triggering A note on alarm re triggering As soon as an alarm is triggered the corresponding delay time but not any others resets to zero and alarm proce...

Страница 20: ...Time zone and MKT values Following specifically influences the appearance of the PDF file l Scaling parameters for the chart l Showing or hiding grid lines l Showing or hiding alarm threshold lines l...

Страница 21: ...r of the UTREL30 WiFi l Clearing and resetting alarms when the START CLEAR STOP button is pressed l Leaving the alarm turned on even if readings return to the normal temperature range again l Allowing...

Страница 22: ...MAC address shown in this screen so it is allowed to connect to the network Factory new units do not contain any settings In this case please use the LogTag Online Connection Wizard to connect the dev...

Страница 23: ...the logger has been configured for other parameters such as logging and alarms When the wizard runs the wireless and network parameters you enter are used to check that the UTREL30 WiFi can establish...

Страница 24: ...be deployed Adding the Probe and the Power Supply Before the UTREL30 WiFi can record temperature data you will need to connect an external probe The UTREL30 WiFi accepts any ST10 probe including an S...

Страница 25: ...or you if you provide your sign in details when you run the Wizard You can also register the device by signing in to your LogTag Online account at https logtagonline com and completing the steps for d...

Страница 26: ...If a logger is scheduled to take a temperature reading and also upload readings to the server at the same time the temperature reading will always be taken first before the upload starts l If the logg...

Страница 27: ...ad the connection is re established automatically at the next scheduled data upload to the LogTag Online cloud server This symbol shows the status of the last connection to the LogTag Online cloud ser...

Страница 28: ...the server such as the current time l upload any new temperature and event data that have been recorded since the last connection to the cloud server l close the connection This will give you immedia...

Страница 29: ...ection to the LogTag Online cloud server Cloud symbol shows a tick The UTREL30 WiFi is now exchanging data with LogTag Online indicated by an arrow inside the cloud symbol The arrow may turn on and of...

Страница 30: ...ooting on the next page for further details This connection test is performed automatically every time the UTREL30 WiFi takes the first reading of a new trip You can initiate this test manually at any...

Страница 31: ...lp narrow down which part of the upload process fails The UTREL30 WiFi is trying to access the wireless network but has not yet successfully connected If you see this icon on the display for more than...

Страница 32: ...entication method At present the UTREL30 WiFi can only connect to wireless networks with WEP or WPA WPA2 access without enterprise functions Contact your distributor if you need to connect the UTREL30...

Страница 33: ...or and run the LogTag Online Connection Wizard again selecting Advanced Setup l No IP address or DNS server configured Please re run the LogTag Online Connection Wizard select Advanced Setup and enter...

Страница 34: ...AX Temperature Data These two temperatures represent the minimum and maximum since the recording started or since the values were last manually cleared Main Temperature Value This shows the most recen...

Страница 35: ...until the start l If is shown the UTREL30 WiFi is recording temperature at the sample interval defined during configuration l If is shown together with the word PAUSED the product is also recording bu...

Страница 36: ...minimum recorded temperature for the day displayed MIN and MAX are also shown next to the minimum and maximum values during recording if these are enabled Above Below Threshold Arrows The up arrow is...

Страница 37: ...wer be unavailable for example in the event of a power cut If used as a backup the batteries have a life span of approximately 6 to 12 months depending on the time the unit operates without external U...

Страница 38: ...partially charged battery will drain the secondary backup battery Rechargeable AAA cells are not recommended for this product The different charge voltage means the battery indicator will not show th...

Страница 39: ...stopped and a scheduled date time start will proceed and l Min Max values cannot be cleared After pressing any button following is shown on the display l The Recording state indicators which show if t...

Страница 40: ...ediately when the low battery symbol as shown appears This can be done by a qualified technician Failing to replace the battery can result in loss of configuration information and loss of recorded dat...

Страница 41: ...quently to preserve battery life5 until the alarm is cleared the unit stops or is re configured Note The interval will increase even if the alarm is re triggered Please see more information about re t...

Страница 42: ...ming discontinuous which would be the case if the real time clock were to be changed together with the display clock The UTREL30 WiFi s real time clock regularly synchronizes with the LogTag Online se...

Страница 43: ...ton start the current time and READY are shown together with the Backup Battery Status symbol The power symbol is shown when the unit is connected to a USB power supply WiFi and cloud connection symbo...

Страница 44: ...logger has been configured for a push button start with a start delay the word STARTING DELAY is shown instead of the symbol The delay time is shown in hours and minutes The time counts down and the...

Страница 45: ...time start If you configured the UTREL30 WiFi for a date time start it will start recording temperature values as soon as the entered start time is reached Until then the logger will display the scre...

Страница 46: ...i and cloud connection symbols are also shown Following are some sample display screens At 1 25 pm l Alarm events were recorded 6 18 19 27 days ago The following symbols show on the display o for the...

Страница 47: ...re visible but the alarm remains present as it has not been inspected and cleared l The day summary has shifted by 1 day as the display time has passed through midnight 00 00 This means some of the we...

Страница 48: ...days Day 12 1 week and 5 days Day 13 1 week and 6 days Day 14 2 weeks Day 15 2 weeks and 1 day Day 16 2 weeks and 2 days Day 17 2 weeks and 3 days Day 18 2 weeks and 4 days Day 19 2 weeks and 5 days D...

Страница 49: ...e of day the inspection took place Clearing an Alarm During configuration with LogTag Analyzer you can allow users to clear an alarm on the display This is a useful function for an inspector so repeat...

Страница 50: ...on the time of day the alarm was cleared Note Only the Alarm Indicator can be cleared The day alarm marker in the above example remains shown as it is part of the statistic summary Clearing an alarm a...

Страница 51: ...PAUSED will turn off as soon as the last ignored reading has been recorded The option is set in the Advanced Settings tab during configuration with LogTag Analyzer and is expressed in number of readi...

Страница 52: ...r a complete day the minimum and maximum statistics for that day will show on the display and in the list Power Save When Power Save is enabled the display will automatically switch off if none of the...

Страница 53: ...not be reset and the currently stored min max values will be retained if l you keep holding the button for more than 2 seconds after the dashes no longer blink or l you release the button within the i...

Страница 54: ...button displays the current day s maximum statistic l The Today marker flashes to indicate that today s data is being displayed l Today no temperature values were recorded above the upper alarm thresh...

Страница 55: ...corded yesterday was 57 3 C Pressing the button now displays yesterday s minimum statistic l flashes as we are still looking at yesterday s data l Yesterday no temperature values were recorded below t...

Страница 56: ...m event was generated l The minimum temperature recorded on the day before yesterday was 74 8 C Data from 6 days ago After pressing the button for a few times skipping days 3 to 5 the maximum statisti...

Страница 57: ...icated by the upper alarm threshold marker l The duration was 5 hours 20 minutes l An alarm event was generated indicated by the symbol Neither duration from day 6 or day 7 alone would cause an alarm...

Страница 58: ...ays Day 11 1 week and 4 days Day 12 1 week and 5 days Day 13 1 week and 6 days Day 14 2 weeks Day 15 2 weeks and 1 day Day 16 2 weeks and 2 days Day 17 2 weeks and 3 days Day 18 2 weeks and 4 days Day...

Страница 59: ...igure a UTREL30 WiFi so it can be stopped with the START CLEAR STOP button This feature is useful when you take the logger out of a shipment and don t want to falsify the statistics with readings take...

Страница 60: ...re readings Once the logger has stopped the last alarm status before the logger stopped will continue to be indicated with a cross or a tick symbol on the display but the audible alarm and the alarm L...

Страница 61: ...0 WiFi does not generate files l USB Input Device HID Driver This device is used for communication to LogTag Analyzer and its driver will always be installed even if LogTag Analyzer is not present on...

Страница 62: ...Fi You can access the files by browsing to the newly created drive and double clicking the PDF CSV or LTD files l For PDF files you need Adobe Acrobat Reader or a similar PDF viewer l To open the LTD...

Страница 63: ...his shows at a glance if the UTREL30 WiFi recorded alarm conditions during the trip showing a red or if no alarms were recorded showing a green Recorded Data Overview This section shows at what time t...

Страница 64: ...EL30 WiFi would otherwise have taken a reading The list shows instead of the reading Recorded Data Chart The chart shows a graphical representation of the data during the trip As part of the UTREL30 W...

Страница 65: ...lds are shown with red dashed lines so you can see at a glance where temperatures went above set limits You may see up to three lines depending on configuration and zoom settings Lower Threshold Lines...

Страница 66: ...om the report page is repeated here Recorded Data list The Data list shows a single row for each recorded reading along with the date time and temperature values plus any special events that were reco...

Страница 67: ...d any button was pressed during recording l A symbol will be shown where a reading could not be taken due to USB communication with a PC l A symbol will be shown when the min max readings were reset S...

Страница 68: ...inimum and maximum for the day l Whether or not an alarm was recorded for that day l If the minimum and maximum temperatures were above or below the thresholds l How long temperatures were outside the...

Страница 69: ...k the logger must be STOPPED Press and hold the START CLEAR STOP button The READY symbol will turn on When the STOPPED symbol turns off release the button within 2 seconds The logger is now ready to b...

Страница 70: ...he LogTag menu Initially the display shows SLP on the display until you remove the logger from the USB port A hibernated logger has no active display however a button press will wake the logger up bri...

Страница 71: ...aircraft airplane mode can be turned off using the exact same procedure l Press and hold the FN and START CLEAR STOP buttons simultaneously l Keep holding the buttons while the Airplane mode symbol on...

Страница 72: ...quiv to 2 5 seconds day Rated temperature coefficient is 0 034 0 006ppm C i e typically 0 00294seconds day C Recording Capacity 16 129 real time temperature values giving l 67 days 6 min logging l 112...

Страница 73: ...e 141 mm H x 72 mm W x 18 mm T Weight without probe 134 g without batteries approx 158 g with 2 x AAA batteries Calibration Factory calibration using instruments traceable to an ISO IEC 17025 accredit...

Страница 74: ...rature accuracy of a UTREL30 WiFi Figure 4 Rated Temperature Accuracy Chart Temperature Resolution The following graph shows the typical rated native temperature resolution of a UTREL30 WiFi Figure 5...

Страница 75: ...f recorded values that need to be alarm readings for the trigger condition to be met Alarm Event Single occurrence of an alarm Alarm Range Temperature humidity range that is outside the Non Alarm rang...

Страница 76: ...ton on a logging device Inspection Event Pressing the Mark button on a logging device Instant Alarm One single temperature or humidity reading is above or below the configured threshold L Latched Aler...

Страница 77: ...umidity readings are above or below the configured threshold for the time defined without interruption T Tertiary Alarm The alarm threshold third closest to the non alarm range U Upper Alarm An alarm...