Содержание LFC60W10

Страница 1: ...1 LOGIK LFC60W10 SKU 154677 Refrigerator and freezer service manual MODEL RD 38WC4S BCD 295WY HC...

Страница 2: ...tions 2 5 2 Specification 5 5 3 Parts identification 6 6 4 Cooling system diagram 7 7 5 Circuit diagram 8 8 6 Maintenance service and Troubleshooting 8 15 7 Quality information report 16 16 8 Exploded...

Страница 3: ...3...

Страница 4: ...4...

Страница 5: ...C4SFY net capacity L 295 color white power supply V Hz 220 240 Defrost power W 190 net weight kg 80 gross weight kg 88 unit dimension W D H mm 595X664X1834 packing dimension W D H mm 643 703 1905 cont...

Страница 6: ...6 3 Parts identification...

Страница 7: ...7 4 Cooling system diagram when the refrigeration is just powered on The refrigerant flows in the sequence Compressor Condenser Dry filter Capillary tube Evaporator...

Страница 8: ...r inside the cabinet Considering the Sensor connecting or cutting problem in order to check the problem easier we get the display error to distinguish the problem when we design the product When the d...

Страница 9: ...the multimeter with the ohm switch to measure the resistor of sensor normally at surrounding 25 the resistor should be about 2kohm and every with the temperature decreases 1 the corresponding resistor...

Страница 10: ...sistor of sensor if sensor is bad change a new one Or else go on next step Measure the resistor of plug If the resistance figure shows infinity that means connection between the main board and plug ha...

Страница 11: ...electron box cover Checking the connection of main board have problem or not The solution for E2 problem Open the door and put out all the drawers Remove the wind channel plate in freezer chamber Put...

Страница 12: ...refrigeration system blocked by ice or dirty please stop the unit and restart after 10 minutes to see if the compressor can start Weak cooling effects 2 1 Is there any heat source around the refriger...

Страница 13: ...ated food 6 3 Whether the internal cabinet needs cleaning the forefront or the middle cabinet heats 7 1 As fridge Anti condensation tube is placed here and caused the above phenomenon which is normal...

Страница 14: ...the discharging tube to see if you can block the gas coming out of the tube when compressor is working Change a new compressor 5 There is something that blocked the liquid cycle system Some time ther...

Страница 15: ...vaporator defrosts The pressure of absorbing becomes negative Higher temperature of discharging tube The way to check offal blocking If you warm capillary with the way of checking ice blocking there i...

Страница 16: ...provide you with more satisfied products please kindly fill in the questionnaire as the items indicated below We shall strive for best to optimize our products based on your suggestion Client name Sa...