RTCU LX5 eco Technical Manual V1.00
Advanced Industrial M2M/IoT Gateway
Logic IO ApS.
Ph: (+45) 7625 0210
Holmboes Allé 14
Fax: (+45) 7625 0211
8700 Horsens
Page 27 of 33
Email: [email protected]
Denmark
Power Consumption
The table below shows detailed information about the RTCU LX5 eco device's typical power
consumption while it is running.
Typical power consumption: Device operating in normal mode
12V
24V
BAT
Device active
50
30
120
mA
Device active with Cellular on*
55
32
125
mA
idle @ -51dBm* 42G)
Device active with GPRS session*
190
100
430
mA
@ -51dBm,
Battery not charging*
Device active with GNSS on
70
35
160
mA
Mode 3
Device active with RF sending
60
30
125
mA
Device active while charging
400
200
-
mA
Note:
Values marked with (*) are averaged and should be considered guidelines as they may vary
depending on the cellular signal strength. The power consumption from the battery @ 3.8V
The table below shows detailed information about the RTCU LX5 eco device's typical power
consumption in power-saving modes.
The following power-saving modes are used:
➢
Mode 1: LED blinks every ~10 s, resumes the application when it is awoken.
➢
Power down: The device is powered down.
See the RTCU IDE on-line manual for information about how to use the power-saving modes.
Wake-up source
Mode 1
Power down
12V
24V
BAT
12V
24V
BAT
Cellular
2
1.5
5
-
-
-
mA
CAN (Write enabled)
8.5
4.5
20
-
-
-
mA
CAN (Write disabled)
6.9
3.7
16.5
-
-
-
mA
RS232 Mode 1
1.1
0.7
2.2
-
-
-
mA
RS485 Mode 1
1.7
1
4
-
-
-
mA
RF
8.1
4.5
21
-
-
-
mA
Vibration
1.1
0.75
3
-
-
-
mA
Din 1/Ignition
1.1
0.7
3
0.5
0.3
0.7
mA
Din 2-3
1.1
0.7
3
-
-
-
mA
Power Failure
1.1
0.7
3
-
-
-
mA
Power Apply
1.1
0.7
3
0.5
0.3
0.7
mA
Time
1.1
0.7
3
0.5
0.3
0.7
mA
Note:
Power consumption from the battery @ 3.8V
Note:
Values marked with (*) are averaged and should be considered guidelines as they may vary
depending on the signal strength.