Maintenance
34
www.loepfe.com
YarnMaster PRISMA
5.2
Replacing sensing head
ü
Replacement sensing head is included.
1. Stop the relevant and adjacent spindles.
2. Switch off the power supply to the spindles.
3. Remove the covers from the relevant spindles.
4. Disconnect the sensing head cable from the spindle adapter.
5. Remove defective sensing head.
6. Replace sensing head.
7. Connect sensing head cable to spindle adapter.
8. Insert covers at the corresponding spindle.
9. Switch on the power supply to the spindle.
10. If PC is displayed on the TK display after changing the scanner, update the firmware.
11. Adjust the relevant spindles.
12. Start the spindles.
5.3
Replacing spindle adapter
ESD symbol
Electrostatically sensitive components
NOTE
Danger to electronic components due to electrostatic
discharge.
Improper handling of electronic components can cause damage that leads to
complete failure or sporadic errors.
4
Observe the general ESD protection measures when installing and repairing
the product.
4
Only touch the edges of the printed circuit boards.
4
Do not touch the printed circuit board and connector plugs.
4
Place removed components on an antistatic surface or in an antistatic
shielding container.
4
Avoid contact between printed circuit boards and clothing.
ü
Spare spindle adapter included.
1. Stop the relevant and adjacent spindles.
2. Switch off the power supply to the spindles.
3. Remove the covers from the relevant spindles.
4. Disconnect all cables at the spindle adapter.
5. Remove the defective spindle adapter.
6. Change the spindle adapter.
7. Connect all cables to the spindle adapter.