Installation
26
www.loepfe.com
MillMaster TOP
3.3.6
Schlafhorst Informator AC338
1. Connect an RJ45 cable directly to the Mini surface box to use the software.
Informator AC338 rear panel
3.3.7
Schlafhorst Informator with series number < 7000
Informators delivered before the end of January 2004 also require a transceiver to
connect to the machine.
Informator units delivered after February 2004 have a built-in transceiver.
1. Connect an RJ45 cable to the Informator interface to use the software. (See figure: Informator rear
panel.)
Informator rear panel
Check battery
Prerequisites
ü
The battery level must not be too low to configure the settings.
ü
Do not switch off the machine while editing settings.
1. Stop the machine.
2. Activate the Informator’s screen.
3. Open the
Service > Maintenance
menu.
4. Check the battery level.
ð
The battery level should be > 3000 mV.