Installation
MillMaster TOP
www.loepfe.com
15
3.3
Configuring central units and connecting them to the
network
This section describes the different connections to the network and the associated configurations for the
central units.
The software can be connected to the following central units and Informator units:
n
Central unit: LZE-I, LZE-II, LZE-III and LZE-V
n
Machine type: Schlafhorst AC 338 and Schlafhorst Oerlikon AC5, ACX5 and AC6 Informators
Requirements for configuration and network connection
n
RJ45 cables are available.
n
Plan at least 0.5 meters (1 foot 8 inches) of additional RJ45 cable length.
n
RJ45 cables are laid in a cable tray or other appropriate device.
n
RJ45 cables are not laid together with cables that carry a live voltage.
3.3.1
IP addresses
This section provides suggestions and examples of IP addresses and subnet masks that can be used to
connect the winding machines.
No.
Machine
name
IP
addresses
Subnet mask
Host
name
LZE
type
Yarn
clearer
type
Spindle
PC
MillMaster
192.168.7.1
255.255.255.0
01
Winding ma-
chine 1
192.168.7.101
255.255.255.0
02
Winding ma-
chine 2
192.168.7.102
255.255.255.0
Notes:
Table 1: Example IP addresses and subnet masks
The following local IP address ranges are also available; these ranges are not reachable on the Internet
and can therefore be used for the software.
IP addresses
10.0.0.0 – 10.255.255.255
172.16.0.0 – 172.31.255.255
192.168.0.0 – 192.168.255.255
Table 2: Examples of additional IP addresses