5.2 Set Up
5.2.1 Purging Air from the Syringe
To avoid air bubbles during dispensing, the tip of the syringe must be purged of
air.
Hold the syringe over a container since product will flow out!
Press the power switch to the position I (ON).
Using the pressure regulator
(2)
, set the dispensing pressure to 0.50 bar (approx.
7.00 psi).The set dispense pressure will show on the digital display.
Press the
button until the display reads MANUAL.
Press and hold the
button (or foot switch) until the product flows free of
bubbles from the dispense needle
If the product drips out of the dispense needle:
Slowly turn the vacuum regulator
(4)
counter clockwise until the dripping stops.
Do not continue turning after the dripping has stopped. When air is sucked in,
the syringe must again be purged of air and curing of the product can occur!
This can also cause the product to be sucked back into the unit and will damage it.
5.2.2 Manual Mode
This mode gives the operator full control of each dispense cycle.
Press the
button until the display reads MANUAL.
Using the pressure regulator
(2)
, set the dispensing pressure to 0.50 bar (approx. 7
psi).
Press and hold the
button (or foot switch) until the desired dispense quantity
is achieved.