background image

 

EQUIPMENT 

 

 

 

 

 

 

 

 

Instruction Sheet 

 

 

 

4-Way Solenoid Valve Kit (Mounted Air Applicator) Installation Guide 
 
Part No. 986326   4-Way Solenoid Valve,    24 VDC 

     989358   4-Way Solenoid Valve, 115 VAC 
     989359   4-Way Solenoid Valve,

 

230 VAC

 

 

Installation of 4-way solenoid valve to mounted air applicator

  

 

Note: 

First determine the best location for the solenoid valve keeping in mind the hose 

location and the mounting of the air applicator. Maintain some distance between 
solenoid valve and heated applicator body to reduce heat radiation. 

 
1.  If position of the dispense valve is not optimum, the back portion of the 

applicator can be rotated in any of four positions. Remove the screws evenly 
and rotate the body section to the desired position and re-install the four 
screws. Use care not to bind the body as this may cause damage to the needle. 

2.  (A) Place the compression nuts and sleeves over the two aluminum tubes and 

insert between the applicator head and air solenoid valve (4 places). Tighten 
the compression nuts using two ½” open end wrenches until snug. 
 

TIP:

 When bending the tubing to fit the location, try to form over the side of 

your hand, as the tubing will kink easily if just bent. 
 

3. 

(B) Align and connect the solenoid valve electrical connector to the mounted 
air applicator electrical connector. Rotate the locking nut fully to make 
connection.

 

4. 

Connect a filtered, regulated air supply line to the solenoid valve inlet port.

 

 
 
 