Содержание 98413

Страница 1: ...413 that meet ANSI Z80 3 Z87 1 Certification Observe safety precautions as listed in the equipment manual Protective eyewear equipped with side shields are required Warning UV Energy is transmitted from this unit UV 7411 S Loctite Zeta 7411 S UV Flood Curing System Part Number 98413 ...

Страница 2: ... 1 Operation 4 2 2 System Components 4 3 Technical Data 4 3 1 Specifications 4 4 Installation 5 4 1 Unpacking and Inspection 5 4 2 Installation and Startup 5 5 Operation 6 5 1 Controls and Operation 6 6 Troubleshooting 7 7 Care and Maintenance 8 7 1 Maintenance 8 8 Documentation 9 8 1 Wiring Diagram 9 8 2 Spare Parts List 9 9 Warranty 10 ...

Страница 3: ...properly The following guidelines should be followed at all times to ensure protection from the ultraviolet light 1 UV protective glasses with side shields should be worn when working with and around the lamp system Glasses should meet ANSI Z87 1 certification 2 Potentially exposed skin should be covered Long sleeves and protective gloves should be worn when placing and removing parts from under t...

Страница 4: ...ing potting tacking and sealing applications Because of its reliability and simplicity it is well suited for most production operations The system irradiates medium power long wave ultraviolet light over an 8 x 8 inch work area An optional visible light enhanced lamp is also available for use with Loctite visible light curing products refer to spare parts list The major components of the system in...

Страница 5: ...ION JACK FOR USE WITH UV INTENSITY MONITOR ONLY 3 Technical Data 3 1 Specifications Loctite Model ZETA 7411 S Loctite Part Number 98413 Electrical Power Required 120 VAC 60 Hz single phase 8 Amps Lamp Type 400 Watt Metal Halide visible and UV enhanced Power Supply Dimensions L x W x H inches 11 25 x 12 x 5 Power Supply Weight 17 4 Pounds Irradiator Lamp Housing Dimensions L x W x H inches 11 x 11 ...

Страница 6: ... UV protective glasses at all times while operating the system A pair is supplied with the unit To energize the system turn the power switch on and allow 5 minutes for the lamp to reach full power To maximize lamp life the unit should be kept under power without frequent on off cycling It is suggested that the lamp remain on during work breaks The lamp should be allowed to operate a minimum of 15 ...

Страница 7: ...te Zeta Meter 7010 part 98001 can be used to monitor performance In addition to the system configuration of lamp base attached to power supply the system can be run as a power supply separate from the lamp base assembly A six foot extension cable is also available from Loctite part 985022 With the lamp turned off the lamp head and base can be taken off the power supply and operated at bench level ...

Страница 8: ...formance As an alternative regular inspection of the cured product may provide an indirect and less accurate measure of lamp function If a radiometer is not used to track lamp life the lamp should be replaced at least after every 1 000 hours of operation To remove the lamp first remove the lamp head assembly and place on a work surface with the filter glass facing up Remove the four screws that ho...

Страница 9: ...GSCREW HOLD WIRES TOGETHERBEFORE INSERTING NOTE USE MECHANICAL CRIMP TO UV LAMP FAN RED WIRE BLACK WIRE BLACK WIRE BLACK WIRE BLACK WIRE W H IT E W IR E W H IT E W IR E WHITE WIRE WHITE WIRE BLACK WIRE J2 7 3 5 1 6 2 8 4 18 AWG GREEN YELLOW 8 TOGROUND STUD 8 2 Spare Parts List Item Part Number UV Enhanced Metal Halide Lamp 97246 Visible Light Enhanced Metal Halide Lamp 983050 Glass Filter Kit 9850...

Страница 10: ...s for use in connection with the Products are available from Henkel the use of products parts or attachments which are not manufactured by Henkel no claim shall be allowed No Products shall be returned to Henkel for any reason without prior written approval from Henkel Products shall be returned freight prepaid in accordance with instructions from Henkel NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WH...

Страница 11: ... P 55090 Ecatepac de Morelos Edo de México Henkel Corporation Automotive Metals HQ 32100 Stephenson Hwy Madison Heights MI 48071 Henkel Ltda Rua Karl Huller 136 Jd Canhema 09941 410 Diadema SP Brazil www loctite com Loctite is a trademark of Henkel Corporation U S A Copyright 2004 Henkel Corporation All rights reserved Data in this operation manual is subject to change without notice Manual P N 98...